EN-20
Settings of 1 to 5000 seconds are available. Default is 1. Printing occurs at the defined time interval.
MT-Continuous
Continuous
If MT-Continuous is selected, the print output will be in the MT-Continuous format.
mMt.CO
NOTE: Refer to 10.1 MT Standard Continuous Output for MT-Continuous format.
OH-Continuous
If OH-Continuous is selected, the print output will be in the OH-Continuous format.
NOTE: Refer to 10.3 OH-Continuous Print for OH-Continuous format.
OH.CON
UPS
Courier 5000 scale can be compatible with UPS WorldShip software when UPS is selected.
Mode
Set the printing conditions.
LOad
= prints when the displayed load is stable.
LOA2E
= prints when the displayed load and zero reading are stable.
Stable Only
Set the printing criteria.
OFF
= values are printed immediately, regardless of stability.
On
= values are printed only when the stability criteria is met.
Content
Define the content of the printed data.
Result
Set the status.
OFF
= disabled
On
= the displayed reading is printed
Gross
Set the status.
= disabled
OFF
On
= the gross weight is printed
Net
Set the status.
OFF
= disabled
On
= the net weight is printed
Tare
Set the status.
= disabled
OFF
On
= the Tare weight is printed
Header
Set the status.
OFF
= disabled
On
= the Header is printed
NOTE: Refer to 10.2 OHAUS Commands, you will know how to enter the header line.
Footer
Set the status.
OFF
= disabled
= the Footer is printed
On
= printing occurs continuously.
= printing occurs continuously.
= printing occurs continuously.