10.1
SYSTEM MESSAGES
The wheel balancer can show messages to the
operator. These may be error related (E-codes) or
warnings (H-codes). The codes will be described in the
following chapters.
Whenever a code appears:
• Make a note of it;
• Look up the code in the list. If the code is not
described, call service team;
• Perform the steps described.
In special cases, or if the need arises, some operating
modes or states can be changed by entering the
appropriate codes (C Codes).
36
10.1.1 C CODES
Selecting and changing a code.
Example for code C0 (Fig. 7-1)
•
Press and hold down together the "MODE" (7) and
"FINE" (8) keys for 7 seconds.
The C codes selection condition appears.
•
Press one of the "+" or "-" keys until the readout
shows the desired code number (e.g.: C 0).
•
Press the ENTER key (5) to acquire the selection.
The right number readout shows the current state,
e.
g.:
"0" which in this case means switched off.
If the desired state is already on the readout:
•
Press the STOP key
to C codes selection (Fig. 7-2), and a second time
to defi nitively exit and return to the operating mode.
If the desired state is not that shown by the readout,
but needs selecting, proceed as follows:
•
Press one of the "+" or "-" keys until the right readout
shows the desired condition
Now two options are possible:
Option 1
•
Press the ENTER key to acquire the selection.
•
Press the STOP key to return to the operating
mode.
The operating mode change is complete and is saved
until a new setting is entered. When the machine is
switched off the settings are not deleted, and at each
subsequent start up they appear as previously set up
until changed again.
Option 2
Cancel selection of code C just set and return directly
to the operating mode:
•
Press the STOP key twice consecutively.
Note: Code C4, Compensation of the clamping
means, cannot be transferred to the
permanent memory.
Below are the change codes available and the relative
selections possible.
Code C0
Setting operating modes preset by the factory:
• Select Code C0
• Select one of the following options:
0* =
No action
1 =
Set the default values
(state 1 appears briefl y)
EEWB332B
(10, Fig.
7-1) once to return
(e.g.:
"0").