- Only professional technicians must perform installation, complying with all safety
instructions, especially those regarding electrical connections.
- To avoid short circuits, arrange an automatic bipolar switch with opening distance of the
contacts of at least 3 mm before the circuit.
- If not used, the black wire must be insulated. It is dangerous to touch the black wire
when the motor is powered.
Connection
diagram
L
N
PE
E P
1
2 3
1
2
3
PE
Stas 3
CONNECTION
POWER SUPPLY SIDE
1 - NEUTRAL
2 - PHASE
3 - OPTIONAL WIRED SWITCH
PE - EARTH
* Switch with mechanical or electrical interlocking
SAFETY INSTRUCTIONS
ELECTRICAL CONNECTIONS A510034
Wiring with Hirschmann connectors
Connection for optional
wired switch*
WINDTEC - Ref. A520007
WINDTEC LUX - Ref. A520008
Stak 3
1
2
3
PE
35
GIRO Series
SKIPPER Series
POP Series
CONNECTION
MOTOR SIDE
1 - COMMON
2 - UP (or Down)
3 - DOWN (or Up)
PE - EARTH