SMART MODE - motors with mechanical limit switches
SHORT-TERM SETTING OF A REMOTE CONTROL AND SETTING
THE ROTATION DIRECTION OF THE MOTOR
This function makes it possible to store a remote control temporarily, for example, with
the purpose of setting the limit switches during assembly in the factory. A later final
saving of the remote control will be possible using the appropriate command sequence
(see: "SETTING THE FIRST REMOTE CONTROL"). The operations described below can
be carried out only when the control unit has just come out of the factory or after a
full memory clearing (see: "FULL MEMORY CLEARING"). The control unit makes the
following operations possible only within the time limits described in order to make sure
that the short-term setting is used only in the installation or factory setting phase and not
during daily use. Power up the control unit, make sure that no other control units having
an empty memory are powered up in the same operating range.
Within 30 seconds after start, press the B and C buttons simultaneously until the
motor gives a confirmation signal.
T1: First remote control to be stored
After the last confirmation movement the motor starts to move in one direction (UP or
DOWN). To properly associate the UP and DOWN buttons, press the button corresponding
to the motor movement for one second as indicated below:
?
The remote control will remain stored for 5 minutes, while the control unit is
powered up. After 5 minutes or when the control unit has its power cut off, the remote
SPECIAL FUNCTIONS
+
B
C
T1
control will be cancelled.
A
C
T1 (1 sec)
51
The motor stops: the
UP and DOWN buttons
are
now
properly
associated.