SMART MODE - motors with mechanical limit switches
OPENING SLATS WITH OR WITHOUT AUTOMATIC LOWERING
The control unit may be programmed to open the slats to a preferred position, with or
without the complete lowering of the blind. Choice of this mode enables the control unit
to be set up based on the user's habits.
• Automatic lowering enables, with a single command, to completely lower the blind,
followed by opening of the slats.
• The choice to turn off automatic lowering enables the slats to be set to the user's
preferred position, leaving the blind in whatever position it might be.
• If automatic lowering is turned off, two separate commands are required to open the
slats on completely lowered blind: the command to close the blind completely and then
the command to open the slats.
Type of opening
With
With
lowering
Factory
settings
Without
Without
lowering
+
B
C
OPEN COMMAND
B
< 2 sec
Execution and automatic movements
For 2- or 3-position tilt mechanisms (excluding CH
Black): the motor completely lowers the blind to its
lower limit, then opens.
For the CH Black tilt mechanism: first the 3rd position
is reactivated, then the blind is lowered completely.
For 2- or 3-position tilt mechanisms (excluding CH Black):
the motor lowers the blind for about 2 s, then opens.
For the CH Black tilt mechanism: the 3rd position is
reactivated.
+
B
C
To give the open command, with the motor stopped, just
give a brief stop impulse (<2 s). The motor will make a brief
confirmation movement, then with the release of the button
it will perform the movements required to open the slats,
depending on what kind of tilt mechanism has been set.
45
with
C
2 sec
A
without
2 sec

Publicidad

loading