Installation And Connection - TECshow NAVIGATOR EXPERT RDM Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5. Installation And Connection

Switch off the DMX controller prior to connecting any units
or to changing any existing connections
5. Installation And Connection
Installation
Install the unit on a plane surface or in your rack. When
choosing the installation spot make sure that there is
enough space around the unit for ventilation or that heat-
ed air from the rack can be passed on to improve heat radi-
ation. Steady overheating will damage the unit.
Use a DMX cable and 3-pin XLR plugs and connectors in or-
der to connect the controller to the DMX chain. If you wish
to connect fixtures with other XLR outputs, you need to use
adapter cables.
1.
Connect the DMX output of the controller to the
DMX input of the first light effect unit.
2.
Connect the DMX output of the first fixture in the
DMX chain to the DMX input of the next fixture.
Always connect one output to the input of the
next fixture until all fixtures are connected.
3.
At the last fixture, the DMX cable has to be termi-
nated with a terminator. For this solder a 120 re-
sistor between signal (–) and signal (+) into a
3-pin XLR plug and plug it in the DMX output of
the last fixture.
4.
If the cable length exceeds 300 m or the number of
DMX devices is greater than 32, it is recommended
to insert a DMX level amplifier to ensure proper
data transmission.
5.
Finally connect the device to the mains with the
mains cable.