EN
Contents
­ Index ­ General warnings ­ Conformity declaration
Overview
Contents
Function
Installation
Start up
Service
Overview
Important notes
The MAX burners are designed for the
combustion of domestic fuel oil EL in
accordance with EN267 standards.
Assembly, commissioning and
maintenance must be carried out only by
authorised specialists and all applicable
guidelines and regulations must be
observed.
Burner description
The MAX burner is a single-stage, fully-
automatic monoblock-type burner. It is
suitable for use, within its range of
performance, with boilers complying with
EN 303 or hot-air generators in line with
DIN 4794, DIN 30697 or EN 621.
Use for any other application requires the
approval of Ecoflam.
Ecoflam burners have been designed and built in compliance with all current regulations and directives.
All burners comply to the safety and energy saving operation regulations within the standard
of their respective performance range. The quality is guaranteed by a quality and management system certified in accordance with ISO
9001:2008.
6
www.ecoflam­burners.com
Technical data
Working fields
Dimensions
Index
General warnings
Conformity declaration
Burner description
General safety functions
E-BCU OIL control and safety unit
Oil burner pump
Burner assembly
Electrical connection
Checks before commissioning
Oil feeding and suction line
Setting data table - air regulation
Adjusting burner output
Oil pressure regulation
Maintenance
Troubleshooting
Electrical diagrams
Spare parts list
The following standards should be
observed in order to ensure safe,
environmentally sound and energy-efficient
operation:
EN 226
Connection of vaporising oil and forced
draught gas burners to the heat generator.
EN 60335­2
Safety of electrical equipment for domestic
use.
Installation location
The burner must not be operated in rooms
containing aggressive vapours (e.g. spray,
perchloroethylene, hydrocarbon
tetrachloride, solvent, etc.) or tending to
heavy dust formation or high air humidity.
Adequate ventilation must be provided at
the place of installation of the furnace
system to ensure a reliable supply with
combustion air.
Variations may arise as a result of local
regulations.
3
Declaration of conformity for oil
burners
4
5
We,
Ecoflam Bruciatori S.p.A.
6
6
declare under our sole responsibility
6
that the light oil burners named
7
MAX
8
conform to the following standards:
9
EN 267
10
EN 55014­1
EN 60335­1
11
EN 61000­6­2
12
These products bear the CE mark in
12
accordance with the stipulations of the
following directives:
13
2014/35/UE Low Voltage Directive
2014/30/UE EMC Directive
14
2006/42/EC Machine directive
15
2011/65/EU RoHS2 directive
(EU) 2016/426 Gas Appliance
15
Regulation.
16
17
66
67-68
We can accept no warranty liability
whatsoever for loss, damage or injury
caused by any of the following:
- Inappropriate use.
- Incorrect assembly or repair by the
customer or any third party, including the
fitting of non-original parts.
Provision of the system and the
operating instructions
The firing system manufacturer must
supply the operator of the system with
operating and maintenance instructions on
or before final delivery. These instructions
should be displayed in a prominent
location at the point of installation of the
heat generator, and should include the
address and telephone number of the
nearest customer service centre.
Notes for the operator
The system should be inspected by a
specialist at least once a year. It is
advisable to take out a maintenance
contract to guarantee regular servicing.
420010617900
EN 50156­1
EN 55014­2
EN 60335­2­102
EN 61000­6­3