4.7 - Flexible pipe option
Minimum bending radius:
non-insulated pipes 7 mm
insulated pipes 106 mm.
4.8 - optional electric heater
WARNING: Disconnect the power supply before carrying
out any work on the unit.
If the electric heater develops a fault, it must be replaced;
this requires the removal of the fan motor assembly: Fig. 17
(17a = screw).
CAUTION: Do not touch the live metal heater elements
when the electric heater is connected to the power supply.
5 - CODIFICATION
Codification (last digit)
or option 600
Red wire
Grey wire
Black wire
Wire marked L
NOTE: Terminal 1 = highest speed, Terminal 6 = lowest speed.
Product reference
4
Digit
1
0
5
A
2 pipes right
1
0
B
2 pipes left
2
1
C
4 pipes right
2
2
D
4 pipes left
2
3
E
2 pipes/2 wires, right, low pressure
3
1
F
2 pipes/2 wires left, low pressure
3
2
G
2 pipes/2 wires, right, high pressure
3
3
H
2 pipes/2 wires left, high pressure
B
Modular unit with 2 supply air spigots
C
Modular unit with 3 supply air spigots
G
Modular unit with 1 supply air spigot at the end (in-line configuration)
H
Modular unit with 1 supply air spigot at the side (opposite coil)
J
Modular unit with 4 supply air spigots
K
Modular unit with 5 supply air spigots
M
Return air plenum 1 spigot and modular unit 1 supply air spigot (in-line configuration)
N
Return air plenum 1 spigot and modular unit 1 supply air spigot (U-shape configuration)
P
Return air plenum 2 spigots and modular unit 2 supply air spigots
Q
Return air plenum 3 spigots and modular unit 3 supply air spigots
R
Return air plenum 4 spigots and modular unit 4 supply air spigots
S
Return air plenum 5 spigots and modular unit 5 supply air spigots
T
Compact unit with 1 return air spigot and 1 supply air spigot
U
Compact unit with 2 return air spigots and 2 supply air spigots
V
Compact unit with 3 return air spigots and 3 supply air spigots
1
Fan motor speed wiring
Terminal marking (standard wiring), option 600 not selected
Product type
Size
2
E
M
N
N
2
3
4
5
6
-
None
C
2-way valve
D
4-way valve
J
2-way valve + flexible piping
K
4-way valve + flexible piping
Electric heater replacement procedure:
Remove the filter.
Remove the fan motor assembly access panel.
Identify and note the fan speeds wired to the auto-
transformer terminal block. Disconnect the power
supply cable.
Remove the fan motor assembly.
NOTE: Be careful not to touch the fan blades during
the removal process to avoid unbalancing the fans.
Disconnect the electric heater power supply cables
and remove them through the cable conduit.
Unscrew the defective heater(s) and replace it (them).
Replacement of the fan motor assembly is by the
reversal of the above procedure.
C
A
A
A
A
7
8
9
10
11
-
A
0
None
B
A
230 V on/off
C
D
E
F
G
-
None
A
NTC
B
HDB
D
NTC + IAQ board
E
Terminal block with plastic cover
F
E + relay
G
E + relay + fuse holder
K
NTC + fuse holder
L
NTC + IAQ board + fuse holder
M
HDB + fuse holder
R
E + fuse holder
A
A
A
A
A
12
13
14
15
16
A
G3 rear access
B
G3 access from below
-
None
A
125 mm ø fresh air spigot only
B
8.3 l/s (30 m
C
16.6-44.4 l/s (21/28/36) 60-160 m
None
(75/100/130)
Return air sensor
E
Motorised fresh air valve adapter ø
Supply air sensor
125 mm
Change-over sensor
J
125 mm ø fresh air spigot only
A + B
K
8.3 l/s (30 m
A + B + C
L
16.6-44.4 l/s (21/28/36) 60-160 m
A + C
(75/100/130)
B + C
N
Motorised fresh air valve adapter ø
125 mm
W
Six wired
speeds
Variable-speed
LEC motor
/h)
3
/h
3
/h)
3
/h
3

Publicidad

loading

Este manual también es adecuado para:

Atmosphera 42em t1Atmosphera 42em t2Atmosphera 42em t3