Saeco MEGACOLD L Instrucciones De Uso página 79

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

MEGACOLD L– Issue 01
Command 68 Setting displayed currency description :
The command allows the operator to set the desired currency. 4 characters are available and they are
entered using the same method as described for Command 95.
Command 69 Chooses functioning mode of the coin mechanism:
This command chooses the type and mode of functioning of the coin mechanism. The parameter can
assume the following values:
0
System EXECUTIVE with prices controlled in the machine (see relevant paragraph).
1
System EXECUTIVE in PRICE HOLDING mode (i.e. prices programmed in the coin mechanism). In
this case, the prices programmed at command 03 and those programmed in the coin mechanism
must be the same (see relevant paragraph). Alternatively you can set the "Price-Display" parameter.
If enabled, the vending machine will utilize exclusively the information on the price value deriving from
the payment system, that is, it will not be necessary to fill in the price tables (Commands 03 and 04);
simply set only Command 05 (see relevant paragraph).
4
System BDV 001 (see paragraph using the coin mechanism BDV)
5
Payment system MDB (see paragraph on using the MDB payment system).
Command 70 Buzzer operation option:
By setting this command at zero the buzzer is disconnected during machine operation.
Command 73 Enabling the photoelectric cells:
This command should be set at 1 only if the photoelectric cell system is installed. Its function is to
enable=1/disable=0 this device. Note: This setting is valid for both machines (MASTER and SLAVE).
Set the command at 1 (photocells enabled), to automatically access the menu which allows this function to be
disabled if necessary for the desired selections (delivery without photocell control). To disable the option
corresponding to one or more selections, simply key in the selection number and then set the value at zero.
N.B.: with the SPIRAL SLAVE connection enabled (see Command 49), after setting the MASTER machine,
the same parameters for the SLAVE machine can be set.
Command 74 Photocell test:
This command is used to test that the photocells are functioning correctly. A test procedure is started
automatically, then at the end of the procedure, if there are no problems a single value appears which
corresponds to the magnitude of the incoming signal. If there is a problem with the functioning, a second
value appears on the display which refers to the problem. See the table for Command 99 for this second
value.
Command 75 Setting the operating parameters of the photocell barrier :
This command allows the operator to view and change the operating parameter of the photocell barrier. This
value is the same for the MASTER machine and any connected SLAVE machines.
Message
Default value
"Hyster.HL"
6
Command 76 System's operating options ("FTC Options "):
Setting this command determines how the machine will react if the product is not delivered. The value can be
set at between 0 and 2. Default = 0.
The meaning of the setting is as follows:
0 = Possibility of another selection; in this case command 63 (single-multisale) must be set at 1 (if it is an
executive payment system the multisale must also be set in the payment system).
1 = Automatic credit delivery; in this case command 63 must be set at 0 (if it is an executive payment system
the single sale must also be set in the payment system).
2 = Further quarter turn: if the product is not delivered the spiral completes a further 1/4 turn and if the
product has still not been delivered then the machine reverts to one of the preceding two options depending
on the single or multisale parameter that has been set.
For this purpose once the value 2 has been set in command 76, the option is disabled for all the
selections by default. Then you automatically access the menu that allows you to enable the option for
the individual spirals. To enable the option corresponding to a spiral simply enter the selection number
Meaning
This parameter acts on the sensitivity of the reading of the system.
The lower the value set in this parameter , the greater the sensitivity
of the system. The value can vary from a minimum of 5 to a
maximum of 30.
29
E
N
G
L
I
S
H

Publicidad

Tabla de contenido
loading

Tabla de contenido