10.8 ACCESS TO THE ELECTRIC PANEL AND REFRIGERATION UNIT

To access the electric panel or the refrigeration unit proceed as follows:
Switch off the machine by means of the main switch and pull out the power plug.
Open the door.
Use a phillips screwdriver to undo the two screws that fasten the product collection pocket to the cabinet.
Remove the pocket.
To remove the refrigeration unit, lower the two levers located on the side of the evaporator box, ensure
that the gasket positioned on the top edge of the evaporator box is not attached to its lodging, pull the
special handle. CAUTION : beware of the cables.
E
N
G
L
I
S
H

10.9 BOTTLE UNLOADING KIT

CAUTION: the bottle discharge bar must not be used to pull-out
the tray.

10.10 INSTRUCTIONS FOR REPLACING THE INTERNAL LIGHTING DEVICE

Electric panel: When the product collection pocket is removed the entire vending
machine remains energised. To disconnect the power remove the red key inserted in the
terminal board. Total isolation from the electric power supply is only obtained when the
plug is removed from the external magnetothermal switch. Consequently, all operations
required by the vending machine without the protection of the product collection pocket,
must only be carried out by qualified personnel who are aware of the specific hazards
which this condition involves.
Switch off the machine by means of the main switch and disconnect the plug.
Open the main door.
Remove the cover from the light source.
Replace the light source.
Carry out the operations in reverse order to reassemble.