CONTROL PANEL (diagram C)
The meanings of the different control panel elements are
summarized on the following tables, where:
• O means lit LED light.
• ( ( O ) ) means slow-flashing.
• (((O))) means fast-flashing.
DISPLAY
Is showed on screen instantaneous
OPERATION
pressure or instantaneous current
MODE
consumption
Is displayed on screen the adjusted start
pressure blinking.
ADJUSTMENT
Is displayed on screen the adjusted stop
MODE
pressure blinking.
Is displayed the adjusted rated current
blinking (only SW2).
ALARM MODE Is displayed the alarm code
STAND-BY
Are displayed 3 flashing dots
MODE
BASIC CON-
Is displayed the sequence of basic confi-
FIGURATION
guration parameters
MODE
ADVANCED
Is displayed the sequence of advanced
CONFIGURA-
configuration parameters
TION MODE
LEDS
STATE
It indicates the instantaneous pres-
O
sure in bar
bar
It indicates the instantaneous pres-
( ( O ) )
sure in bar +
SW1)
It indicates the instantaneous pres-
O
sure in psi
psi
It indicates the instantaneous pres-
( ( O ) )
sure in psi +
SW1)
It indicates the instantaneous cu-
A
O
rrent consumption in Ampere units
(only
SW2)
( ( O ) ) Pump ON
O
Is displayed the start pressure
START
( ( O ) ) Adjusting start pressure
O
Is displayed the stop pressure
STOP
( ( O ) ) Adjusting stop pressure
Ratified dry-running or overload
O
alarms
Dry-running alarm performing ART
( ( O ) )
or overload alarm preforming any of
the 4 restore attempts
(((O)))
Fast-cycling alarm
ACTION
MEANING
pump operating (only
pump operating (only
P-BUT-
TOUCH
TON
click!
HOLD
DOWN
click!
3"
click!
3"
click!
3"
STARTUP (diagram C)
Before starting the device please read the previous
sections, especially "Hydraulic Installation" and "Elec-
trical connection".
Follow next steps:
1. Only for type SW2 set the pump rated current intensity
value.
- Press
during 3 seconds.
- The current intensity value is displayed on screen, LED
A lights up and display is flashing.
- By mean of
and
reflected in the characteristics plate of the motor. See
Note 1.
- Press
for validation.
2. Start the device by pressing
3. Set the cut-in (start) pressure:
- Press
during 3 seconds.
- The start pressure value is displayed on screen, LED
START lights up and display is flashing.
- By mean of
and
from 0,5 to 7 bar.
- Press
for validation.
4. Set the cut-out (stop) pressure:
- Press
during 3 seconds.
- The stop pressure value is displayed on screen, LED
STOP lights up and display is flashing.
- By mean of
and
from 1 to 8 bar.
- Press
for validation.
5. The unit is ready to operate but more optional ad-
justments can be set through basic and advanced MENUS.
See the next chapter.
Remark 1: it is important to introduce exactly the ra-
ted current specified on the nameplate of the pump.
8
ACTION
From state ON: unit OFF.
From state OFF: the pump starts
and keeps operating until rea-
ching Pstop.
From any configuration MENU:
the parameter value is accepted.
From state ON: unit OFF.
From state OFF: the pump starts
and keeps operating until the
push-button is released.
Pstart is displayed on the screen
for 3 seconds.
Pstart adjustment mode.
Pstop is displayed on the screen
for 3 seconds.
Pstop adjustment mode.
Is displayed on the screen instanta-
neous current consumption.
If it is already displayed then we
switch to instantaneous pressure
view.
Rated current adjustment.
is adjusted the rated current
.
is adjusted the start pressure
is adjusted the stop pressure