Descargar Imprimir esta página

Selco Genesis 2200 PMC Instrucciones De Uso página 42

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 117
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
552
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
601
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
602
CH1, CH2, CH3, CH4 External parameter
Allows the management of external parameter 1, 2, 3, 4
(minimum value, maximum value, default value, param-
eter selected).
(Consult the "External controls management" section).
751
Current reading
Allow the real value of the welding current to be dis-
played.
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
List of set up parameters (Standard MIG/MAG,
Pulsed MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the synergic MIG process by setting
the type of material to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22 m/min, Default 1.0m/
min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
5
Part thickness
Allows the thickness of the part being welded to be set.
Allows the setting of the system via the regulation of the
part being welded.
6
Corner bead
Lets you set bead depth in a corner joint.
7
Voltage
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Minimum 5V, Maximum 55.5V
Minimum -9.9V, Maximum +9.9V, Default syn
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
11
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
42
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50%
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15
Burn back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, Maximum +2.00, Default 0.00
16
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
19
Duty cycle (double pulsed)
Permit adjustment of the duty cycle in double pulse.
Parameter setting: percentage (%).
Minimum 10%, Maximum 90%, Default 50%
20
Double pulsed
Allows enablement of the "Double Pulsed" function.
Allows regulation of the pulsation amplitude.
Parameter setting: percentage (%).
Minimum 0%, Maximum 100%, Default ±25%
Parameter setting: meters per minute (m/min).
Minimum 0.5m/min, Maximum 22m/min, Default
2.5m/min
21
Pulse frequency
Allows regulation of the cycle, i.e. of the impulse rep-
etition cycle.
Allows the impulse frequency to be regulated.
Minimum 0.1Hz, Maximum 5.0Hz, Default 2.0Hz
22
Secondary voltage
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during the
various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
23
Pulsed slopes (double pulsed)
Allows setting of a slope time during the pulse operation.
Parameter setting: percentage (%).
Minimum 1%, Maximum 100%, Default 50%
24
Bilevel (4 Step - crater filler)
Permits adjustment of the secondary wire speed in the
bilevel welding mode.
If the welder now presses and releases the button quickly,
"
" can be used; by pressing and releasing it quickly
again, "
" is used again, and so on.
Parameter setting: Percentage (%).
Minimum 1%, Maximum 500%, Default off

Publicidad

loading