Descargar Imprimir esta página

Selco Genesis 2200 PMC Instrucciones De Uso página 43

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 117
25
Initial increment
Allows regulation of the wire speed value during the first
"crater-filler" welding phase.
Makes it possible to increase the energy supplied to the
part during the phase when the material (still cold) requires
more heat in order to melt evenly.
Minimum 20%, Maximum 200%, Default 120%
26
Crater filler
Allows regulation of the wire speed value during the weld
closing phase.
Makes it possible to reduce the energy supplied to the part
during the phase when the material is already very hot,
thus reducing the risk of unwanted deformations.
Minimum 20%, Maximum 200%, Default 80%
27
Initial increment time
Lets you set the initial increment time. Lets you auto-
mate the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
28
Crater filler time
Lets you set the "crater filler" time. Lets you automate
the "crater filler" function.
Minimum 0.1s, Maximum 99.9s, Default Off
30
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31
Pause point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
32
Secondary voltage (MIG Bilevel)
Allows regulation of the secondary pulsation level voltage.
Makes it possible to obtain greater arc stability during
the various pulsation phases.
Minimum -5.0, Maximum +5.0, Default syn
33
Secondary inductance (MIG Bilevel)
Allows regulation of the secondary pulsation level
inductance.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
34
Initial increase slope
Allows to set a gradual transition between the initial
wire speed and the welding wire speed.
Parameter setting: seconds (sec.).
Minimum 0 sec., Maximum 10 sec., Default Off
35
Crater filler slope
Allows to set a gradual transition between the welding
wire speed and crater filler wire speed.
Parameter setting: seconds (sec.).
Minimum 0 sec., Maximum 10 sec., Default Off
202
Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder's movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, Maximum +30, Default syn
331
Voltage
Lets you set welding voltage.
399
Welding speed
Lets you set welding speed.
Minimum 20cm/min, Maximum 200cm/min, Default
35cm/min (reference speed for manual welding).
Syn: allows automatic setting of the welding parameters
using the robot speed value on an analog input.
(Consult the "System configuration" section - Set up
Service).
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
Allows access to the higher set-up levels:
USER: user
SERV: service
SELCO: Selco
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
552
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
601
Regulation step
Allows the regulation of a parameter with a step that can
be personalised by the operator.
Minimum 1, Maximum Imax, Default 1
602
External parameter CH1, CH2, CH3, CH4
Allows the management of external parameter 1, 2, 3,
4 (minimum value, maximum value, default value,
parameter selected).
(Consult the "External controls management" section).
606
U/D torch
Allows the management of the external parameter
(U/D).
O=off, I=current, 2=program retrieval
705
Circuit resistance calibration
Lets you calibrate the system.
Press the encoder knob to access parameter 705.
Place the tip of the wire guide in electrical contact with
the work piece.
Press and hold the torch trigger for at least 1 s.
751
Current reading
Allow the real value of the welding current to be dis-
played.
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
757
Wire speed reading
Allow the value of the motor encoder 1 to be displayed.
760
(Motor) Current reading
Allow the real value of the (motor) current to be dis-
played.
801
Guard limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the "Guard limits" section).
43

Publicidad

loading