Descargar Imprimir esta página

Selco Genesis 2200 PMC Instrucciones De Uso página 46

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 117
Confirm the operation by pressing button (1)
Cancel the operation by pressing button (2)
3.9 Interface personalisation
Allows the parameters to be customized on the main menu.
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
PROCESS
PARAMETER
MMA
XE
TIG DC
LIFT START
MIG/MAG
Pulsed MIG
MMA
XA
TIG DC
LIFT START
MIG/MAG
Pulsed MIG
MMA
XP
TIG DC
LIFT START
MIG/MAG
Pulsed MIG
46
.
.
(
)
(
)
(
)
1
7 segment display personalisation
Enter set-up by pressing the encoder button for at least
5 seconds.
Select the required parameter by rotating the encoder.
Store the selected parameter in the 7 segment display
by pressing button (2)
Save and exit the current screen by pressing button (4)
.
Default I1
3.10 Lock/unlock
Allows all the settings to be locked from the control panel with
a security password.
Enter set-up by pressing the encoder key for at least 5 seconds.
Select the required parameter (551).
Activate the regulation of the selected parameter by pressing the
encoder button.
Set a numerical code (password) by rotating the encoder.
Confirm the change made by pressing the encoder button.
Save and exit the current screen by pressing button (4)
The carrying out of any operation on a locked control panel
causes a special screen to appear.
.
.

Publicidad

loading