Fiac SSA 410 Manual De Uso Y Mantenimiento página 22

Electrocompresores insonorizados de pistón
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
GB
Display visualization
On
Means the unit is ON with low load;
On
Means the unit is ON with normal load;
On
Means the unit is ON with normal-high load;
On
Means the unit is ON with high load;
Segnalling leds
LED
Key functions
TEST: Pushed for 3 sec. during normal operation, it allows to activate a condensate drainage cycle.
SET: When pushed and released during normal operation, it displays the set-point value (decimal).
When pushed for 10 seconds, it allows to enter the C8 and C9 condensate drain parameters programming menu (see
relevant table).
When pushed after having set new configuration values, it stores the applied modifications.
DOWN: When pushed while setting the set point or the configuration parameters, it decreases the displayed value of one
unit per second, during the first 10 seconds, than of one unit every 0,1 sec.
When pushed for 10 seconds during normal operation, it starts an automatic test cycle of the controller.
.
UP: When pushed while setting the set point or the configuration parameters, it increases the displayed value of one unit
per second, during the first 10 seconds, than of one unit every 0,1 sec.
ON / OFF: Pushed for 3 seconds, it activates or deactivates the process. When the process is deactivated, the display
shows OFF.
NOTE: when the controller is in OFF position, some parts of the dryer are kept under tension therefore, for safety purposes,
disconnect the electrical power before performing any operation on the machine.
TEST
SET
STATUS
ON
Blinking
ON
ON
Blinking
22
LOAD
%
DEW POINT
LEVEL
DESCRIPTION
Compressor energized
Programming mode activated
Condensate drain energized
Speed of the fan = 100%
Speed of the fan < 100%