ENGLISH
tion operation, also pointing out the actions to be taken in case of
emergency.
18) MAINTENANCE
WARNING! Before proceeding to any maintenance, disconnect the mains
power supply and, if the battery is fitted, one of its poles.
These are the check and maintenance operations to be carried out:
• Check the condition of lubrication of the metal racks once a year.
• Keep the sliding track always clean and free from debris.
• Occasionally clean the photocell optical elements.
• Have a qualified technician (installer) check the correct torque limit set-
ting.
• When any operational malfunction if found, and not resolved, disconnect
the mains power supply and request the assistance of a qualified tech-
nician (installer). When the automation controller is out of service, you
can activate the manual release device (see paragraph on "Emergency
manoeuvre") in order to set the pinion idling and therefore allow the gate
to be opened and closed by hand.
19) NOISE
The environmental noise produced by the gear-motor in normal operation
conditions is constant and does not exceed 70 dB (A).
20) SCRAPPING
Materials must be disposed of in conformity with the current regulations.
In case of scrapping, the automation devices do not entail any particular risks
or danger. In case of materials to be recycled, these should be sorted out by
type (electrical components, batteries, copper, aluminium, plastic etc.).
21) DISMANTLING
When the automation system is disassembled to be reassembled on another
site, proceed as follows:
• Disconnect the power supply and the entire electrical installation.
• Remove the gearmotor from its fixing base.
• Disassemble the control panel, if separate, and all installation compo-
nents.
• In the case where some of the components cannot be removed or are
damaged, they must be replaced.
22) MALFUNCTIONS AND REMEDIES
22.1) Faulty actuator operation
• Use an appropriate instrument to check that the actuator ends are supplied
with voltage after the opening or closing command.
• If the leaf movement is opposite to that required, reverse the motor drive
connections in the control unit.
22.2) Faulty operation of electrical accessories
In case of fault, all the control and safety devices can cause the automation
controller to malfunction or lock. If the control unit is provided with self-diag-
nosing facility, identify the fault. If a fault is found, it is advisable to disconnect
and, if necessary, bridge, all the automation control devices one by one, until
the one causing the fault is identified. Replace or repair it, then reset all the
devices which were previously disconnected or bridged. For all the devices
installed, make reference to the respective instruction manual.
WARNING! Correct controller operation is only ensured when the data
contained in the present manual are observed.The company is not to be
held responsible for any damage resulting from failure to observe the
standards relating to safety, installation and good technical practice,
as well as the instructions contained in the present manual.
The descriptions and illustrations contained in the present manual are
not binding. The Company reserves the right to make any alterations
deemed appropriate for the technical, manufacturing and commercial
improvement of the product, while leaving the essential product fea-
tures unchanged, at any time and without undertaking to update the
present publication.
16 - ICARO Ver.04
INSTALLATION MANUAL