12. ENDING WORK
After you have ended your work, push the handle upright
until the release lever clicks (1 FIG.7).
Let the brush spin for a few seconds with the handle
upright, in order to allow it to dry.
Turn the machine off by means of the switch (1 FIG.6)
and pull out the plug to disconnect it from the mains (4
FIG.6).
Empty the tank (1 FIG.9), wash it, dry it and fit it back
onto the machine.
If you wish to empty the detergent tank (5 FIG.2), you
will have to take the pipe from its fitting and drain its
contents.
This operation must be carried out with the
machine turned off and disconnected from
the mains.
FIG.9
FIG.12
ENGLISH (Translation of original instructions)
13. MAINTENANCE
All routine and corrective maintenance
operations must be carried out with the
machine turned off and unplugged from the
mains.
13.1 REMOVING THE BRUSHES
13.1.1 Front brush (FIG.10)
Using a screwdriver, push the pin out of its seat to enable
removal of the brush. After cleaning or to replace an old
brush, push the cleaned or new brush into its seat and
push the pin back into its previous position.
13.1.2 Rear brush (FIG.11)
Proceed as indicated above and in addition remove the
rear tank.
13.2 REMOVING THE BIN
Keep a frequent check of the level of water in the waste
water container to prevent any leakages from occurring
during operation. For this purpose, remove the container
(part 1 of FIG.12). This is done by giving it a light push it
upwards to knock it out its seat.
After you have carried out your check, put it back in
place and make sure it is firmly fastened.