Section 2
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
Location
Potable
Water Inlet
Potable
Water Drain
Condenser
Water Inlet
Condenser
Water Drain
Bin Drain
Large Capacity Bin Drain
SEPARATE BIN AND ICE
MACHINE DRAINS ARE
REQUIRED
ROUTE DRAIN TUBING TO
OPEN SITE DRAIN
MODULAR UNITS
Part Number 000017542 Rev 00 8/22
Water Temp
Min/Max
37°/90°F
(3°/32°C)
---
37°/90°F
(3°/32°C)
---
---
---
VENT TUBE
18" (46 CM)
LONG
Typical Water Supply Drain Installation
Water Pressure
Min/Max
20/80 psi
(138/552 kPA)
---
20/150 psi
(138/1034 kPA)
---
---
---
WATER SHUT-OFF VALVE
REQUIRED - ICE MAKING
WATER INLET TUBING 3/8"
MIN. I.D. (.95 CM)
ICE MAKING WATER
INLET TUBING 3/8"
MIN. I.D. (.95 CM)
VENT TUBE
18" (46 CM)
LONG
UNDERCOUNTER UNITS
Installation Instructions
Fitting/Min Tubing Size
3/8" FPT
1/2" MPT
3/8" FPT
RFF2500 only = 1/2" FPT
1/2" MPT
3/4" FPT
1" FPT
ROUTE
DRAIN
TUBING TO
OPEN SITE
DRAIN
15