BABY FAS – Issue 04
7.6.3
CONNECTING A COFFEE VENDING MACHINE TO A BABY FAS VENDING MACHINE BY
MEANS OF A RELAY INTERFACE
The activation of 6 relays connected as shown in the attached drawing (see FIG. 8) for a period of time
determined by the user can be associated to the selections 61 – 66. The activation time of each relay is set
through command 50 and can vary from 10 to 250 hundredths of a second; if the value is set at "0" the
function is disabled.
Example:
If you want to associate the activation of its corresponding associated relay to selection 63 for a time of 1
second, proceed as follows:
1. Programming mode, the screen displays .................................................................................Command 00
2. Key in 50 and press B, the screen displays .................................................................. Selection number 00
3. Key in 63 and press B, the screen displays .......................................................................... time relay NNN
4. Set the value 100 and press B.
Caution: when the relay is activated the price which corresponds to the selection
is deducted from the credit, without any possibility of recovery if the operation
does not succeed.
FAS INTERNATIONAL S.p.A. Via Lago di Vico, 60 SCHIO (VI) – tel. +39 0445 502011 – fax +39 0445 502010 - e-mail: info@fas.it
FIG. 8