Dustguard™ System Water Filter Cleaning (Optional); Hydraulic System Oil Level Check - Nilfisk Advance SW5500 Instrucciones De Uso

Ocultar thumbs Ver también para Advance SW5500:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
DUSTGUARD™ SYSTEM WATER FILTER CLEANING (OPTIONAL)
NOTE
To prevent water from flowing out when cleaning the
filter, turn on the dust guard system and empty the
system tank (23).
1.
Drive the machine on a level ground.
2.
Turn the ignition key (51) to "0" and engage the parking
brake.
3.
Lift and remove the left side panel (32) to reach the water
filter assembly (A, Fig. 22) of the dust control system.
4.
Unscrew and remove the transparent cover (B) with the
gasket (C), then remove the filter strainer (D).
5.
Clean and install them on the support (E).
NOTE
Install the gasket (C) and the filter strainer (D) in
the housings of the cover and of the filter assembly
holder.

HYDRAULIC SYSTEM OIL LEVEL CHECK

WARNING!
Procedure to be performed with the hopper (11)
fully retracted.
1.
Turn the ignition key (51) to "0" and engage the parking
brake.
2.
Open the battery compartment hood (19) and fasten it with
the support rod (47).
3.
Check that the oil level in the hydraulic system tank (46) is
between the minimum (MIN) and maximum (MAX) marks
shown in figure 23.
4.
If necessary, add oil through the plug (A), using the oil
specified in Technical Data paragraph.
5.
Remove the support rod (47) and close the hood (19).
30
INSTRUCTIONS FOR USE
SW5500 - 1467284000
E
C
Figure 22
A
MAX
MIN
Figure 23
A
B
D
P100916
P100917
09/2016

Publicidad

Tabla de contenido
loading

Tabla de contenido