Descargar Imprimir esta página

Holex 080066 15 Manual De Instrucciones página 8

Ocultar thumbs Ver también para 080066 15:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 56
HOLEX Hose reel
de
1.
General information
Read and observe the operating instructions, keep them as a reference for
later and ensure they are accessible at all times.
en
2.
Further information
For connection to a compressed air supply and pneumatic tool, comply with the
manufacturer's operating instructions.
bg
3.
Safety
3.1.
GROUPED SAFETY MESSAGES
CAUTION
da
Pressurised components
Risk of injury from hose ends whipping free, damaged hose or Hose reel.
▶ Before performing any maintenance, repairs or cleaning, disconnect Hose reel
from compressed air supply.
fi
▶ Unfasten or tighten pneumatic tool, hose or assemblies only when depressurised.
▶ Never exceed hose's maximum working pressure.
▶ Regularly check that all connections are firmly tightened.
▶ Connect only to a compressed air supply that will cut out before exceeding the
fr
working pressure.
▶ Use pneumatic tools with flow rate limiters.
▶ Disconnect from compressed air supply if hose can no longer be extended or
reeled in.
▶ Disconnect immediately from compressed air supply of Hose reel or Hose are
it
leaking or otherwise faulty.
3.2.
INTENDED USE
 For work in industrial environments.
hr
 For use indoors.
 For use with compressed air.
 Extend Hose only when working with it.
 Never leave a connected pneumatic tool unattended.
lt
 Use only when it is technically in good condition and safe to operate.
 Disconnect all connections after use.
 Fully reel in Hose after use.
 Bracket for mounting on smooth wall or ceiling with load bearing capacity suffi-
nl
cient for Hose reel.
3.3.
REASONABLY FORESEEABLE MISUSE
 Never use Hose reel without first mounting it on a wall or ceiling.
 Do not make any unauthorised changes or modifications.
no
 Do not use in potentially explosive atmospheres.
 Do not use with flammable gas.
 Not for use where there is exposure to intense heat, direct sunlight, naked flames
or liquids.
pl
 Do not pull Hose suddenly.
 Do not use Hose close to sharp edges.
 Lay Hose flat along the floor, do not kink and avoid looping.
pt
3.4.
DUTIES OF THE OPERATING COMPANY
The operating company must ensure that personnel who work on the product com-
ply with the regulations and provisions together with the following instructions:
 National and regional regulations for safety, accident prevention and environ-
ro
mental protection regulations.
 No damaged products are assembled, installed or commissioned.
 The necessary protective equipment is provided.
3.5.
PERSONAL PROTECTIVE EQUIPMENT
sv
Comply with the national and regional regulations for safety and accident preven-
tion. Protective work wear appropriate for the risks associated with the intended
activities must be selected, provided and worn.
 Wear foot protection, protective gloves, hearing protection and safety glasses.
sk
3.6.
QUALIFICATIONS OF PERSONNEL
Specialists for mechanical work
Specialists in the sense of this documentation are persons who are familiar with as-
sembly work, mechanical installation, commissioning, troubleshooting and mainten-
sl
ance of the products and who possess the following qualifications:
 Qualification / training in the field of mechanics as specified in the nationally ap-
plicable regulations.
Trained person
es
Trained persons in the sense of this documentation are persons who have been
trained to perform work in the areas of transport, storage and operation.
4.
Device overview
A
cs
1 Bracket 2 Casing 3 Stop 4 Pneumatic tool connection 5 Compressed air sup-
ply connection
hu
8
5.
Assembly
5.1.
WALL OR CEILING MOUNTING
B
ü Choose wall plugs and screws matching the wall or ceiling.
1. Position bracket on smooth surface and mark two drilling positions.
▶ Do not mount on wall or ceiling more than 3 m above the floor.
2. Drill holes, screw bracket firmly onto mounting surface with suitable screws and
wall plugs.
6.
Operation
6.1.
PULLING OUT THE HOSE
C
1. Slowly pull the Hose out to the desired length.
▶ Take care to pull the Hose out in a straight line.
2. To stop the Hose, pull on the Hose again until the locking mechanism gives an
audible click.
▶ Do not extend past hose end marking.
3. To adjust the hose stop, release the back stop screw of the stop and move it to
the desired position. Then tighten the back stop screw.
6.2.
CONNECTING
1. Connect Hose reel to the compressed air supply. Connect a suitable pneumatic
tool to the pneumatic tool connection.
▶ Comply with the respective manufacturer's operating instructions.
▶ Note the hose's maximum working pressure.
2. Check that all connections are in order.
WARNING! Risk of injury from pressurised hose. Fully relieve hose reel of
pressure after every use. Do not store when pressurised.
6.3.
REELING IN HOSE
D
1. To release fastening, slowly pull Hose until you no longer hear the locking mech-
anism's clicking sound.
▶ Hose slides back into casing at controlled speed.
2. Guide Hose while it is reeling in.
7.
Maintenance
Interval
Maintenance work
Before each use
 Check hose, hose guide
and external compon-
ents for visible signs of
wear.
 Check for leaks using
soap or leak finder
spray.
Immediately
Repair defects and damage
or replace.
Use genuine spare parts
only.
8.
Faults
 Before performing any repairs, maintenance or cleaning, disconnect Hose from
compressed air supply.
Fault
Possible cause
Hose not reeling in
Hose jams or
fully.
catches when reel-
ing in.
Leaks
 Connections or
assemblies
loose or un-
fastened.
 Hose or com-
ponent dam-
aged.
9.
Technical data
Designation
Maximum working pressure
Material of hose
Temperature range
Hose internal diameter
Usable hose length
Connection thread
Weight
Performed by
Trained person
Trained specialist for mech-
anical work.
Contact Hoffmann Group
customer service.
Action
Performed by
Extend Hose to full
Trained person
length, allow it to
reel in freely.
 Identify defect-
Trained specialist for
ive component.
mechanical work
 Shut off up-
Contact Hoffmann
stream valve, re-
Group customer
lieve hose reel
service.
or pressure.
 Retighten con-
nections, as-
sembly.
 Replace hose if
damaged.
Value
300 psi/20 bar
Hybrid polymer
-40°C to +60°C
3/8 inch/10 mm
15 m
3/8 inch BSPT
6.6 kg

Publicidad