AC Power
Cord
AC Gang
Supply
11. AC Power - Multiple Faucet
CAUTION: Risk of electric shock. Make sure the power has
been disconnected before performing the following
procedures.
IMPORTANT! The area in front of the sensor must be free of
objects during the 2 minute learning cycle or the faucet may not
function properly.
Mount the AC gang supply under the counter using two screws
(not supplied). Orient as shown.
Remove the cover.
If needed, cut and strip the ends of faucet wires to length.
Connect the stripped ends to the bottom terminal block (TB2) in
the AC gang supply.
NOTE: If a hard wired installation is required, proceed to the "Hard
Wire Installations" section.
Plug the AC power cord into the wall outlet.
Secure any excess wire under the counter.
Allow 2 minutes for the sensor to cycle through the automatic
sensing distance.
Hard Wire Installations
Kohler Co.
Black
Red
15
1124216-2-C

Publicidad