TERMINAL BLOCK CONNECTIONS

Power connections

TERMINALS
PE
GROUND CONNECTION
MAINS POWER SUPPLY: 220...230V SINGLE-PHASE (L, N),
L1 (L)
220...230V THREE-PHASES (L1, L2, L3)
L2 (N)
L3
R
+DC
Positive of the d.c. circuit
PE
POWER GROUND
U
THREE-PHASE OUTPUT
V
(TO THE MOTOR)
W

Control connections

N.
TERMINALS
REV
1
RUN
2
3
EXTFLT
IN5
4
5
CM-IN
+24 V
6
GND-D
7
LNK+
8
L N K -
9
EARTH
10
11
IN4
OUT-AN
12
+10V
13
IN-Analog
14
GND-A
15
16
OUT1-NC
OUT1-CM
17
18
OUT1-NO
6-GB
FUNCTION
FUNCTION
Reversal
Se b-00=1:
Run
Alarm from outside
Configurable digital input
Digital input common
Aux. power supply for digit. inputs
Reference ground for digit. inputs
RS-485 serial line inputs
Ground connection
Configurable digit. input
Configurable anal. output
Potentiometer voltage for speed ref.
Anal. input for speed ref. (J 11)
Common for analog input/output circuit
Contacts of the configurable output relay
BRAKING RESISTANCE
Backward run
Forward run
P-43
P-42
P-48
0 - 10 V or + / - 10 V Ri = 20 kohm; 0 - 20 mA Ri = 250 ohm
P-44
—————— SIEI ——————

SIGNAL TYPE

Optical couplers: 24 V, 6 mA
24 V +/- 5%
300 mA
Optical coupler: 24 V, 6 mA
0 - 10 V R
= 2 kOhm
load min
10 V +/-5%
10 mA
120 V ac with 0.5 A
or
24 V dc with 1 A

Hide quick links: