INVERTER PARAMETERS
P menu:
C
ODE
P - 9 0
P - 9 0
P - 9 0
P - 9 0
P - 9 0
PID reference
P - 9 1
P - 9 1
P - 9 1
P - 9 1
P - 9 1
PID max. positive error
P - 9 2
P - 9 2
P - 9 2
P - 9 2
P - 9 2
PID max. negative error
P - 9 3
P - 9 3
P - 9 3
P - 9 3
P - 9 3
PID updating time
P - 9 4
P - 9 4
P - 9 4
P - 9 4
P - 9 4
proportional term gain
P - 9 5
P - 9 5
P - 9 5
P - 9 5
P - 9 5
integral action time
P - 9 6
P - 9 6
P - 9 6
P - 9 6
P - 9 6
derivative action time
P - 9 7
P - 9 7
P - 9 7
P - 9 7
P - 9 7
proportional term gain
P - 9 8
P - 9 8
P - 9 8
P - 9 8
P - 9 8
integral action time
P - 9 9
P - 9 9
P - 9 9
P - 9 9
P - 9 9
derivative action time
NOTE : ( * ) the controls can be executed with stopped motor only; ( ** ) the values depend on the
inverter size.
b menu:
It sets the values of ON / OFF parameters; they are divided into three groups, or LEVELS, their access depends on the
code ( 1, 2, 3 ) set via the P - 20 parameter. They all can be modified with stopped motor only
C
ODE
b - 0 0
b - 0 0
b - 0 0
b - 0 0
b - 0 0
run/reversal input configuration
b - 0 1
b - 0 1
b - 0 1
b - 0 1
b - 0 1
stop mode
b - 0 2
b - 0 2
b - 0 2
b - 0 2
b - 0 2
reversal enabling
b - 0 3
b - 0 3
b - 0 3
b - 0 3
b - 0 3
protection
b - 0 4
b - 0 4
b - 0 4
b - 0 4
b - 0 4
reference input reversal
b - 0 5
b - 0 5
b - 0 5
b - 0 5
b - 0 5
current input
b - 0 6
b - 0 6
b - 0 6
b - 0 6
b - 0 6
enabling of motor overload protection (QUIX_V)
b - 0 7
b - 0 7
b - 0 7
b - 0 7
b - 0 7
motor type (QUIX_V)
b - 0 8
b - 0 8
b - 0 8
b - 0 8
b - 0 8
configuration of external alarm input
b - 0 9
b - 0 9
b - 0 9
b - 0 9
b - 0 9
external alarm tripping mode
b - 1 0
b - 1 0
b - 1 0
b - 1 0
b - 1 0
external alarm detection mode
b - 1 1
b - 1 1
b - 1 1
b - 1 1
b - 1 1
autoreset handling in case of external alarm
b - 1 2
b - 1 2
b - 1 2
b - 1 2
b - 1 2
autoreset enabling
b - 1 3
b - 1 3
b - 1 3
b - 1 3
b - 1 3
enabling of autoreset attempt limitation
b - 1 4
b - 1 4
b - 1 4
b - 1 4
b - 1 4
enabling of autoreset of auto zero-setting attempts
b - 1 5
b - 1 5
b - 1 5
b - 1 5
b - 1 5
autoreset alarm contact
b - 1 6
b - 1 6
b - 1 6
b - 1 6
b - 1 6
voltage reduction tripping mode
b - 1 7
b - 1 7
b - 1 7
b - 1 7
b - 1 7
enabling of momentary overload control (QUIX_V)
b - 1 8
b - 1 8
b - 1 8
b - 1 8
b - 1 8
tripping mode of momentary overload control (QUIX_V)
b - 1 9
b - 1 9
b - 1 9
b - 1 9
b - 1 9
enabling of momentary overload alarm (QUIX_V)
b - 2 0
b - 2 0
b - 2 0
b - 2 0
b - 2 0
enabling of braking resistance overload protection
b-21
/
b-22
/
b-23
/
b - 2 4
b - 2 4
b - 2 4
b - 2 4
b - 2 4
stall prevention during acceleration (QUIX_V)
b - 2 5
b - 2 5
b - 2 5
b - 2 5
b - 2 5
stall prevention at constant speed (QUIX_V)
b - 2 6
b - 2 6
b - 2 6
b - 2 6
b - 2 6
stall prevention during deceleration
b - 2 7
b - 2 7
b - 2 7
b - 2 7
b - 2 7
overvoltage prevention
20-GB
(QUIX_V) : parameter available in the QUIXDrive_V version
D
ESCRIPTION
set 1
set 2
D
ESCRIPTION
—————— SIEI ——————
R
ANGE
Livello 3
0,0 - 100,0
0,1 - 100,0
0,1 - 100,0
0,00(=0,005s) - 2,50
0,00 - 99,99
0,00 - 99,99
0,00 - 99,99
0,00 - 99,99
0,00 - 99,99
0,00 - 99,99
R
ANGE
Level 1
0=RUN/REV
0=in ramp
0=off
0=off
0=off
0=0/20mA
0=off
0=standard
0=NO(nor. open)
0=alarm/lock
0=always
Level 2
0=off
0=off
0=off
0=off
0=off
0=always
0=off
0=always
0=off
0=off
Level 3
0=off
0=off
0=off
0=off
P
U
R E S E T
NIT
VALUE
0,1 %
0,0
0,1 %
5,0
0,1 %
5,0
0,01 s
0,00
0,01
0,00
0,01
99,99
0,01
0,00
0,01
0,00
0,01
99,99
0,01
0,00
U
P
NIT
R E S E T
VALUE
1=FWD/REV
0
1=coast
0
1=on
1
1=on
1
1=on
0
1=4/20mA
1
1=on
1
1=servoventilated
0
1=NC(nor.closed)
0
1=inverter disabl.
0
1=run only
0
1=on
0
1=on
0
1=on
0
1=on
0
1=on
1
1=con. sp. only
0
1=on
0
1=con. sp. only
0
1=on
0
1=on
0
1
1=on
1
1=on
1
1=on
0
1=on
P
AGE
30
"
"
"
"
"
"
"
"
"
P
AGE
24
27
"
"
22
22
25
"
27
"
"
"
27/31
31
"
31
23
26
"
"
28
25
"
"
"