At the start-up, the control panel enters the MONITOR mode thus allowing to read the values assumed
by the d parameters. The chart shows how to switch from one menu to the other and how to act on the
parameters inside the menus.
START-UP
MONITOR MODE
PRESSING M
To CHANGE a parameter value: DISPLAY the corresponding code, then confirm via the E key as stated by the
following chart:
CHANGE MODE
PRESSING E
IT CONFIRMS THE VALUE SELECTED VIA THE ⇑ ⇓
KEYS; IT UPDATES THE PARAMETER VALUE ;
THE PARAMETER CODE APPEARS AGAIN
Act as follows to STORE permanently the performed changes:
STORAGE MODE
DISPLAYS
IMMEDIATELY ONE OF
THE d display MENU
PARAMETERS
SWITCHIES FROM d
TO ANOTHER MENU:
F P b C d
PRESSING E
TO CHANGE THE VALUES PRESS THE ⇑
⇓ KEYS. (TO INCREASE THE SCAN
SPEED HOLD THESE KEYS PRESSED)
MEANS THAT THE VALUE HAS
PRESSING M
GO TO C MENU
USING THE ⇑ ⇓ KEYS,
GO TO THE "C-00" CODE AND
PRESS E
USING THE ⇑ ⇓ KEYS,
CHOOSE 7
AND PRESS E
—————— QUIXDrive Inverter ——————
SWITCHES FROM ONE PARAMETER TO
ANOTHER OF d VIA THE ⇑ ⇓ KEYS (THE
PARAMETER VALUE APPEARS APPROX.
1" AFTER THE KEY RELEASE )
INSIDE THE SINGLE MENU, THE ⇑ ⇓ KEYS SELECT
THE CODE CORRESPONDING TO THE DESIRED
THE SELECTED
PARAMETER IS
CONFIRMED AND ITS
REAL VALUE APPEARS
THE FLASHING LED
BEEN CHANGED BUT NOT
PERMANENTLY STORED
IF THE YELLOW LED IS ON, THE
STORAGE IS ALLOWED
FIRST "done
done" APPEARS TO INDICATE THAT THE
done
done
done
CONTROL HAS BEEN ACCEPTED AND
PERFORMED: THE OPERATION IS FINISHED. WHEN
TURNING OFF, THE SETTING REMAINS STORED.
INSTALLATION INSTRUCTIONS
PARAMETER
IF THE YELLOW LED
REMAINS ON; THE
PARAMETER CAN BE
CHANGED
PRESSING M
IT EXITS THE CHANGE MODE
AND RETURNS TO THE
PARAMETE CODE
13-GB