Descargar Imprimir esta página

Oase ProfiClear Premium Fleece Serie Instrucciones De Uso página 70

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 148
ProfiClear Premium Fleece 750
How to proceed:
1. Remove the two screws of the drum motor and tilt the motor up to remove it.
2. Remove the cap nuts M6 on both sides in the container and remove the holders.
3. Remove the ClearWave filter elements.
4. Install the ClearWave filter elements in reverse order.
– Ensure that the filter elements are correctly positioned in the holders at the bottom of the
container.
5. Reinstall the motor and fasten it by retightening both screws.
Proficlear0359
Proficlear0358
70

Publicidad

loading