PLC OPERATING INSTRUCTIONS
Once your unit has been installed by a qualified serviceman and you have
completed the PRE-OPERATION CHECKLIST, you are ready for operation.
The following steps will help you operate your machine safely.
FLUSHING THE SYSTEM:
CAUTION RISK OF UNIT DAMAGE! BE CERTAIN THE GUN & DUAL
LANCE ASSY. ARE NOT CONNECTED TO THE UNIT WHILE
FLUSHING THE SYSTEM.
DEPOSITS TO BE RELEASED FROM THE SYSTEM WHICH
WOULD OBSTRUCT OR DAMAGE THE GUN AND NOZZLE
ASSEMBLY RESULTING IN COSTLY REPAIRS.
1. This unit has a steel coil which, after setting, will cause the water remaining
in the coil from the previous usage to turn brown or black. This water must
be flushed from the system before start-up. This procedure should be
performed without the gun and adjustable pressure dual lance installed.
a. Verify the water supply is on.
b. Move the pump switch to the "ON" position to start the pumping unit.
c. Run the unit for 3-5 minutes.
d. Turn off machine.
e. Once the system is flushed, connect the trigger gun and adjustable
pressure dual lance to the high pressure hose.
COLD WATER OPERATION:
1. Refer to the "Safety Precautions" before starting the unit.
2. Locate the Safety Decals on your unit and heed their warnings.
3. Pointing the trigger gun in a safe direction, unlock the trigger gun, squeeze
the trigger to relieve trapped pressure, and release the trigger.
DANGER RISK OF INJECTION CAUSING SEVERE INJURY! KEEP
CLEAR OF NOZZLE!
FRONT OF NOZZLE! DO NOT DIRECT DISCHARGE STREAM AT
PEOPLE OR PETS!
4. Move the Main Switch to the "ON" position.
5. The remainder of the switches are momentary. Press UP to turn the function
ON. Press DOWN to turn the function OFF. If the Pump Switch is pressed
DOWN to turn the Pump OFF, it will also turn the Burner and Detergent
OFF.
6. Press UP and release the Pump Switch to start the pumping unit.
7. Once the unit has started, perform the following procedures with the gun
triggered.
a. Inspect for system water and oil leaks.
b. Inspect high pressure hoses for leaks. If a leak is found, DO NOT
TOUCH HOSE AT LEAK!!! TURN UNIT OFF IMMEDIATELY! Replace
hose before using the unit. See "Risk of Injection" warnings. Be sure
that all damaged parts are replaced and that the mechanical problems
are corrected prior to operation of the unit.
8. At this point, the unit is operating as a cold water pressure washer. Trigger
the gun several times and try adjusting the water pressure by rotating the
grip on the dual lance. NEVER place hand or fingers in front of the nozzle
or look directly into the nozzle! High pressure water creates a risk of severe
injury!
9. Do not allow the unit to operate in bypass mode (with trigger closed) for
more than three minutes without triggering the gun. Failure to follow this
simple rule can cause premature failure of pump packing seals, resulting
in costly pump repair. Refer to "Features".