32˚F
Operator's Manual
6. Loosen B2 nut, tighten B2 bolt, tighten B2 nut.
7. Loosen B1 nut, tighten B1 bolt, tighten B1 nut.
DELIME COIL:
A loss in pressure may signify that the coil needs to be delimed. Do this
procedure on a periodic basis.
1. Mix non-caustic deliming powder/solution in float tank according to package
directions.
2. Remove the nozzle from the wand. Place a nylon stocking over the wand
assembly to collect debris, then place the wand assembly into the float
tank.
3. Turn the switch to the "Pump" position. Water will circulate throughout the
system and back into the float tank. Allow circulation to continue for 2-4
hours.
4. Turn the switch to the "Off" position. Drain and clean the float tank. Remove
nylon stocking and clean wand assembly.
5. Flush the entire system with clean, fresh water, then replace nozzle into
wand assembly.
6. Dispose of deliming solution according to local, state and national regulations.
TEST VOLTAGE & AMP DRAW: Use a volt meter and amp meter to test the
machine for correct voltage and amperage. If you do not have these instru-
ments or do not know how to use them, this procedure should be performed
by an authorized service technician.
WINTERIZING:
For storage and transportation purposes in subfreezing ambient tempera-
tures, it will be necessary to winterize this unit. This unit must be protected
to the lowest incurred temperature for the following reasons:
WARNING RISK OF UNIT BURSTING. DO NOT STORE / OPERATE
0˚C
1. If any part of the pumping system becomes frozen; excessive pressure may
build up in the unit which could cause the unit to burst resulting in possible
serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below
32°F, you can protect your unit by following one of the procedures listed
below.
AIR BLOWOUT:
1. Remove the nozzle from the wand assembly. Squeeze the trigger until
water ceases to exit the wand assembly.
2. Connect an air fitting from an air hose to the strainer fitting in the float tank.
3. Run compressed air into the system to remove all water from the system.
ANTIFREEZE SOLUTION:
1. Pour a 50/50 mixture of antifreeze and water into the float tank.
2. Place the detergent strainer into 100% antifreeze solution
3. Turn the switch to the "Pump" position. Allow antifreeze to siphon throughout
the system until antifreeze solution exits the outlet. (To ensure the coil is
winterized, antifreeze solution must exit the outlet. Add more 50/50 mixture
to the float tank if necessary.)
UNIT IN A FREEZING ENVIRONMENT!
MAINTENANCE