HYDROSAUNA FUNCTIONS
• This function cannot be activated if the steam bath is active.
• The message indicating the need for cleaning doesn't prevent the steam bath function.
• If the water tank isn't regularly cleaned, some problems on the steam bath functioning
may occur.
Procedure to activate the "anticalcium" function:
• Put the anti-limescale liquid in the reservoir located in the upper part of the cabin, by
the wall.
• After adding the anti-limescale liquid, press the ENTER key to activate the function. A
second message to confirm the function activation is shown on the screen.
• This double confirmation message must show up within 5 seconds, otherwise the
function will be cancelled. This happens to avoid an accidental start up of the function.
• The function activation is indicated by the message "cleaning in progress" .
The cleaning procedure consists of:
• 10 seconds charge till the tank level is reached. If the tank level isn't reached within 90
seconds, the cycle is cancelled.
• The sequence is repeated 4 times, which includes turning on the resistance for 25
seconds and a 10 seconds break.
• Tank outflow for 3 minutes.
• 4 three-minute cycles of tank charge and discharge, with level control.
• Steam bath session for 30 minutes.
• 1:30 minute break with a full tank.
• Charge and discharge for 10 seconds.
• Final discharge for 4 minutes and three impulses of the discharge electrovalve.
After resetting the meter to zero, indicating the working hours of the tank, the message
"End of Cycle" is shown on the screen.
NOTE:
• The anticalcium function blocks all the following functions: hydromassage, showers,
steam bath.
• The other functions such as Audio and Radio are kept active but cannot be changed be
the user.
• From the moment the steam bath is turned off and the anti-limescale is activated, an
interval must be allowed so that the user may exit the cabin during the activation of the
function.
• If there is a power failure during the anti-limescale cycle, as soon as the power is reset,
the cycle restarts the cleaning and no other function may be activated till its end
(showing the message "End of cycle" on the screen).
62
Water hardness [°F]
10 ÷ 20
21 ÷ 30
31 ÷ 40
Frequency of anticalcium cycles
Cleaning frequency [Hours]
20
13
10
Anti-Limescale [Liters]
0,4
0,4
0,4

Publicidad