Installation, Operating and
Maintenance Instructions
Description
Set of cable transition T-SET
KÜ-T1 FT INTEG-EAV 1+3M
including connecting cable
3 m 3-wires for motor
housing plus cover plate
(depends on the faceplate /
material type), plug-in
Frame part cable transition
T-KÜ-T1 RT KABEL 0,6M RNT
for frame power supply
Extension cable T-LB VERL.
KABEL 0,25M RNT ZU KÜ-T1
Motor housing EAV, for re-
trofitting mechanical locking
system AV3, standard
Frame power supply
T-NETZTEILRAHM. 12 V DC
1,5 A (2A/2S)
Figure 3.6.2-6: Installation blueMatic EAV with
integra with control unit and frame power supply
Aug. Winkhaus GmbH & Co. KG ∙ Berkeser Straße 6 ∙ 98617 Meiningen
T +49 369 3950 - 0 ∙ www.winkhaus.de ∙ Subject to technical changes
blueMatic EAV
Do
not connect
external
voltage!
green / yellow = output relay 2 at
230 V AC
grey / pink = input for external potential-
Notice!
Art.-No.
5040511
Description
to
Set, Integra with control unit
5040504
round face plate 20 mm
square face plate 24 mm
5066122
Fingerprint ekey home FS IN 2.0 T
BT + Dekorelement FS IN ED
5009320
Control unit ekey home SE Integra
1 (R20 / E24)
ekey KAB A 3,5 m / 4 x 0,14 RJ / CP,
5038587
Connection between fingerprint
and control unit Integra 1
Fingerprint ekey home
59
X1: Connection
from sash part cable
transition T-KÜ-T1 SET
FT INTEGR-EAV to the
control unit ekey home
integra with 8-pole
plug
X3: Connection from
control unit to the
fingerprint, plug-in
Screw-type terminal,
Connection to motor
housing EAV (relay 1)
white = supply +
brown = supply -
green = switching pulse
white + 12 V DC
brown 0 V
}
green
relay 2 (at integra 2)
yellow
}
external opening
grey
signal
pink
integra 2
free contact (e.g. unlocking
via intercom / open button)
max. 40 m extendable
(min. 0,8 mm²)
ekey WH-EAV
(sash side)
5044744
EN
3
Art.-No.
ekey
101951
101952