5 Controls
38
(5 seconds)
5.3 DISPLAY key, INFO key
The DISPLAY and INFO keys can be used to defi ne
additional settings or display information:
Alternating between °C and °F
Pressing the INFO and STOP keys together alternates the
temperature display between °C to °F.
The
temperature
by
processed exclusively in °C.
Alternating between execution time and temperature
display
While the program is running, the DISPLAY key can
be used to alternate between execution time and
temperature display.
Additional information
Pressing the INFO key displays additional process-related
information:
Current program number
Cumulative operating hours (max. 50,000 hours; 0 hours
at delivery)
Current heating power in %
Error memory, last error displayed
Error memory, second last error displayed
Highest temperature since the start of the current program
If the INFO key is not pressed again for more than
5 seconds, the original process information display
resumes.
the
microcontroller/software