5.3
Filter Cleaning
In order to ensure maximum suction performance, the suction unit has a device for cleaning the fine filter
unit� The cleaning takes approx� 8 sec�
The cleaning is carried out:
• Automatically:
- After the unit is switched on;
- With insufficient suction power (flow velocity falls below an internal limit value);
- If the unit has been operated for more than 8 hours (turbine running time) without switching it off;
• Manually, e�g� before removing the dust drawer to empty it (see chapter 6�2)�
5.3.1
Automatic Filter Cleaning
♦ Suction turbine is stopped�
♦ The symbol "dust drawer" blinks�
♦ "CLEAn" is shown in the display�
♦ An acoustic signal indicates the cleaning is about to commence�
♦ The filter cleaning is performed.
♦ Suction turbine starts again�
After an automatic filter cleaning, in case of a renewed drop of the flow velocity, the next filter
cleaning will be performed only after 2 hours of turbine running time.
5.3.2
Manual Filter Cleaning
⇒ Press the Enter key (30) and keep pressed for 2 sec�
♦ The filter cleaning is performed.
5.4
Setting the Parameter
On delivery, there are parameters set, which in most cases, make it possible to work with the suction unit
without problems� Only in individual cases, if this is not possible, the parameters can be changed�
The setting of various parameters and the execution of a self-diagnosis are carried out in the program-
ming mode�
The display indicates which parameters are set:
MENU
MENU
MENU
A
MENU
B
A
A
B
MENU
B
A
OFF
A
B
ON
B
A
A
B
To set the different parameters, press the Menu key (20, Fig� 2)� The settings
B
A
are confirmed and saved with the Enter key (30, Fig. 2). Successful saving is
acknowledged with an acoustic signal�
If a change is not accepted, pressing the Menu key (20) will abort the program-
ming�
If the word "Default" (32) appears in the display, you can reset the value to the
factory setting (see chapter 6�8) by pressing the [-] and [+] keys at the same
time�
OFF
Perform self-diagnosis (see chapter� 6�4)
ON
/
OFF
OFF
A
B
Acoustic signal (buzzer) on / off
ON
ON
B
A
OFF
B
A
B
Time interval for full display (full) in the dust drawer
ON
B
A
OFF
Setting the automatic switch-on (calibration)
ON
Set after-run (time) for the suction turbine
OFF
resetdefault
resetdefault
OFF
ON
resetdefault
OFF
ON
resetdefault
resetdefault
OFF
OFF
ON
ON
resetdefault
OFF
ON
ON
MENU
A
B
B
A
- 11 -
32
OFF
ON
resetdefault
OFF
31
33
en
ON
Fig. 9