Repair
This motor has a replicable switch and capacitor; kits are available in the event
of a failure. To replace these components, first turn off the pump and disconnect
from power. Then, disassemble the nozzle hanger and junction cover as
shown previously assembled from figures 4 and 5 on pg. 11 and 12. Follow the
instructions provided with the kit to replace the failed component(s). Reassemble
the cover and hanger and reconnect power. Before transferring fuel with the
pump, verify that the motor does turn on and that the pump is properly running in
bypass; if this is the case, the pump is ready for standard operation again.
For more information about replaceable pump components and troubleshooting,
refer to the QR code on page 18.
Taking out of service and dismantling
To remove the pump, disconnect the power and reverse installation steps from
page 14 to 10 in this manual.
EN
17