Descargar Imprimir esta página

GPI G Pro V20-115PO Manual Del Propietario Del Producto página 8

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIFICATIONS ( CONTINUED )
SAFETY TESTING APPROVALS
The V20 has been tested for compliance to the standards issues by Underwriters
Laboratories. The pump utilizes a motor IM050 (or IM050X for PX pump models)
that has been tested for compliance to the standards issues by Underwriters
Laboratories. In addition to UL, the IM050X is compliant with IECEx, and ATEX.
V20
UL 79 (Tenth Edition) Standard for Power-Operated Pumps for Petroleum
Dispensing Products.
IM050 and IM050X
UL 674 (Edition 5): Electric motors and generators for use in hazardous
(classified) locations.
IM050X
IEC Information
Marking string:
Standards used:
IEC 60079-0 (Edition 7.0): Explosive Atmospheres – Part 0: Equipment -
General requirements.
IEC 60079-1 (Edition 7.0): Explosive Atmospheres – Part 1: Equipment
protected by flameproof enclosures "d".
IECEx specific conditions of use:
1.
Flameproof joints are not intended to be repaired.
2.
The special fasteners used as securing bolts for the end bell are made of
Class 12.9 type fasteners. The special fasteners used for electrical cover
plate attachment are made of Class 12.9 type fasteners.
ATEX Information
Marking string:
Standards used:
EN IEC 60079-0: 2018
EN 60079-1: 2014
ATEX specific conditions of use:
1.
Flameproof joints are not intended to be repaired.
2.
The special fasteners used as securing bolts for the end bell are made of
Class 12.9 type fasteners. The special fasteners used for electrical cover
plate attachment are made of Class 12.9 type fasteners.
8
EN
Ex db IIA T4 Gb
5252 E 36TH ST N
IECEx UL 23.0055X
WICHITA, KS 67220
F
ELECTRIC MOTOR FOR
HAZARDOUS LOCATIONS
CLASS I, GROUP D
II 2 G Ex db IIA T4 Gb
DEMKO 19 ATEX 2113X
II 2 G Ex db IIA T4 Gb
Ex db IIA T4 Gb
UL 23 ATEX 3049X
IECEx UL 19.0027X
2809
Mfg.
Date
REFER TO MANUAL FOR WIRING INSTRUCTIONS
30 ON / 30 MIN. OFF DUTY
12 VDC
34 AMPS
G20-012PX
B
2000 RPM
-30ºC < Tamb < +55ºC
OP. TEMP.
CODE T3C
OP. TEMP.
CODE T4
98ºC RISE
0.38 HP

Publicidad