Descargar Imprimir esta página

SMA EV CHARGER 7.4 Manual De Operación página 42

Publicidad

Idiomas disponibles

Idiomas disponibles

7 Commissioning
10. Perform the test of the charging station according to
IEC 61851 with a suitable measuring device for
charging stations. To do this, connect the charging
cable to the measuring device.
11. Fill out the test report according to IEC 61851. An example of a test report can be found at
www.SMA-Solar.com.
12. If necessary, rectify any defects found.
13. After successful testing, connect the charging cable
to the vehicle.
☑ All 3 LEDs light up. The start-up phase begins.
☑ All 3 LEDs go out again after approximately 90 seconds.
☑ Depending on the available power, the green LED pulses or is continuously illuminated.
The vehicle is charged.
14. If the green LED is still flashing, the conditions for activating charging operation are not yet
met. As soon as the conditions for charging are met, the charging station starts charging the
vehicle.
15. If the red LED lights up, an event has occurred. Use the event message to find out which event
has occurred and, if necessary, initiate countermeasures.
16. After charging, disconnect the charging cable from
the vehicle and wrap it around the product.
42
EVCxx-10-BE-en-11
SMA Solar Technology AG
Operating manual

Publicidad

loading

Este manual también es adecuado para:

Ev charger 22Evc7.4-1ac-10Evc22-3ac-10