Descargar Imprimir esta página

Eurocave VOV3 Modo De Empleo página 32

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 57
8 - SPECIFIC FEATURES OF YOUR VIN AU
VERRE ELECTRONIC
II. Operation in manual mode
In order to activate manual mode, it is necessary to turn the locking
and leave the machine unlocked. The logo will start to slowly flash
when the appliance is in this operating mode.
Manual mode allows you to:
ˆ
Change a bottle
ˆ
Pour wine manually, by pressing one of the keys above the
taps.
ˆ
Reset the wine output meter for each bottle to communicate
to the appliance that the bottle is full
When changing a bottle, draw a small amount of wine, by pressing a measure, to clear the pipes
of air and remnants of the previous wine.
If changing wine, clean the circuit- see chapter 5 - IV.
To manually pour wine, press the small, medium or large measure key corresponding to the bottle that you wish to draw wine
from. As long as you maintain pressure on the key, the wine will continue to pour.
The amount of wine poured in manual mode is not taken into account in the end of bottle
calculation.
To reset the meter of the amount poured out of a bottle, simply press the empty
bottle button corresponding to the bottle which you want to reset, the "empty bottle"
indicator will start to flash to confirm the action. It is possible to reset a meter even if
the "empty bottle" indicator is not lit.
To leave manual mode, close the machine and lock it with the central key.
III. Adjusting measures
This mode allows you to set the measures and the size of a bottle. Please note: once the settings have been changed, they become
the machine's new default settings.
To enter adjustment mode, proceed as follows: press and hold down for a long time the "empty bottle" button of the first tap on
the left (see above, point 1), whilst simultaneously unlocking the appliance with the key (point 2), until you hear a beep. The Vin
au Verre logo will then flash rapidly. Once in this mode, you can set:
ˆ
8LI EQSYRX SJ [MRI HIWMVIH JSV IEGL QIEWYVI
ˆ
8LI XSXEP GETEGMX] SJ XLI FSXXPI
This setting can be carried out for each of the eight bottles. To do this, maintain pressure on the button until you obtain the
desired wine measure (it is possible to carry out several successive presses for accurate measure setting).
8LI QIEWYVIW EVI WIX SRI EJXIV XLI SXLIV MX MW RSX TSWWMFPI XS WIX  QIEWYVIW EX XLI WEQI XMQI -X MW EPWS TSWWMFPI YWMRK XLI WEQI
method, to set the end of bottle signal. To do so, fill a bottle of water, place it in the compartment and press the reset button
(the bottle empties) until you obtain the level that you want to set as the low level warning.
Once the measures have been adjusted, lock the door to switch back to automatic mode.
-12-
k e y

Publicidad

loading

Este manual también es adecuado para:

Vov3 electronic