Know "four Air Compressor
READ THiS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING
YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with
the !ocation of various controls and adjustments.
Save this manual for future
reference.
On/Auto/Off
Switch
On/Auto/Off
Switch:
Turn this switch
"On/Auto" to provide automatic
power to the pressure switch and
"Off" to remove power at the end of
each use.
Pressure
Switch: The pressure
switch automatically
starts the
motor when the air tank pressure
drops below the factory set "cut-in"
pressure. The pressure switch stops
the motor when the air tank pressure
reaches the factory set "cut-out"
pressure.
Safety Valve: if the pressure switch
does not shut off the air compressor
at its "cut-out"
pressure setting, the
safety vaIve wil! protect against high
pressure by "popping
out" at its
factory set pressure (slightly higher
than the pressure switch "cut-out"
setting).
Outlet Pressure
Gauge:
The outlet
pressure gauge indicates the air
pressure available at the outlet side
of the regulaton This pressure is
controlled by the regulator and is
always less than or equal to the tank
pressure.
A09713
14-ENG
Tank Pressure
Gauge:
The tank
pressure gauge indicates the reserve
air pressure in the tank.
Regulator:
Controis the air pressure
shown on the outlet pressure
gauge. Pull the knob out and turn
cIockwise to increase pressure
and countercIockwise
to decrease
pressure. When the desired pressure
is reached push knob in to lock in
place.
Universal
Quick=Connect
Body:
The universal quick-connect
body
accepts the three most popular styies
of quick-connect
plugs: industrial,
automotive
(Tru-fiate), and ARC. One
hand push-to-connect
operation
makes connections
simple and easy.
Brain Vamve: The drain valve is
located at the base of the air tank
and is used to drain condensation
at
the end of each use.
Valve