PROBLEM
Motor will not
run.
CAUSE
Motor overtoad protection
switch has tripped
Tank pressure exceeds
)ressure switch "cut-in"
_ressure,
Check valve stuck open.
Loose electrical
connections.
Possible defective motor
or starting capacitor.
Paint spray on internal
motor parts.
Pressure
release
valve
or]
pressure switch has not
unloaded head pressure.
Fuse blown, circuit breaker
tripped.
CORRECTION
Let motor cool off and see
"Motor" paragraph in the
"Service and Adjustment"
section.
Motor will start automatically
when tank pressure drops
beiow "cut-in" pressure of
pressure switch.
Remove and clean, or replace.
Check wiring connection
inside pressure switch and
terminal box area.
Have checked by a Trained
Service Technician.
Have checked by a Trained
Service Technician.
Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.
Bleed the line by pushing the
lever on the pressure switch to
the "Off" positionl if the valve
does not open, replace switch.
1.
Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a
fuse or circuit breaker
with higher rating than
that specified for your
particular branch circuit.
2.
Check for proper fuse. You
should use a time delay
fuse.
3.
Check for low voltage
conditions
and/or proper
extension cord.
4.
Disconnect
the other
electrical appliances from
circuit or operate the
compressor
on its own
branch circuit.
A09713
26-ENG