• The warranty shall not apply in case of misuse of the product.
• Beware that the power circulating in the dry contacts must never exceed the
levels set out previously to avoid damaging or breaking the SWITCH CONNECT
clock.
POWER CONNECTIONS 230V ~ 50HZ
• Terminal 1: Power 230V ~ (phase).
• Terminal 2: Power 230V ~ (neutral).
CONNECTION OF THE BRUSH/CLEANER
Coupling with the filtration pump is carried out directly on the LivePool application, so it
is not necessary to install a wired connection.
• Terminal 3: Connect it downstream of the circuit breaker for the control section (phase).
• Terminal 4: Connect to terminal A1 of the suppresser contactor (Robot/BRUSH).
CONNECTION OF THE LIGHT OUTLET
• Terminal 5: Connect it downstream of the circuit breaker for the control section (phase).
• Terminal 6: Connect it to the primary section (230V ~ 50Hz) of the lighting transformer.
CONNECTION OF THE FILTRATION OUTLET
• Terminal 7: Connect it downstream of the circuit breaker for the control section (phase).
• Terminal 8: Connect it to the A1 terminal of the filter pump contactor.
CONNECTION OF THE TEMPERATURE SENSORS
• Terminal 10: Connect the black wires of the water and air temperature sensors.
• Terminal 20: Connect the yellow wire of the water temperature sensor.
• Terminal 30: Connect the yellow wire of the air temperature sensor.
• Terminal 40: Connect the red wires of the water and air temperature sensors.
INSTALLATION
5