Wall receptacles and power cords
Two power cords are provided with your printer, according to the printer's electrical specifications. If
those cords do not reach your PDU and/or UPS, a certified electrician must install suitable extension
cables on the day of installation.
To make sure you have the right wall socket outlets (wall receptacles) ready for installation, check the
following:
1.
The wall socket outlets must be suitable for printer input ratings. See
on page
2.
The wall socket outlets must be suitable for the power cord plug type used in the country of
installation. The
power cords and the plugs provided with the printer according to the country. To make sure you
have the right wall receptacle, find your country in the appropriate table and check the plug
type.
WARNING!
strip (relocatable power tap) to connect both power cords. Do not damage, cut or repair the
power cord. With a damaged power cord, there is risk of fire and electric shock. Always replace
a damaged power cord with an HP-approved power cord.
Table 2-5
Printer power cord specifications
Country
USA, Canada, Mexico,
Japan, Philippines,
Thailand
International
International – other
* Alternative part numbers are valid with the same specifications and markings.
6
Chapter 2 Site preparation requirements
4.
Table 2-5 Printer power cord specifications on page 6
Use only use the power cord supplied by HP with the printer. Do not use a power
HP Part Number *
8120-6893
8120-6897
8120-6895
Length
Plug type
4.5 m
NEMA 6-20P, 240 V, 20
A, non-locking
4.5 m
IEC 60309, 240 V, 16 A,
2L+PE
4.5 m
Stripped end termination,
240 V, 1.5 mm² cross
sectional area
WARNING!
A
qualified electrician must
attach a suitable plug
according to local laws
where the printer is
installed, and to the
printer's electrical
requirements.
Single phase power
list examples of the
Plug