HID207
User Manual
Ice Making and Ice Dispensing System Cleaning Instructions Cont'd
12. This is a greaseless bearing. Black oxidation may
be present which is normal; check for any and
wipe way. Inspect the bearing seal for wear and
rust. Call for service if any is found.
Bearing
13. Wash the ice sweep and lower part of the breaker
with the scale remover solution. Remove as much
scale as possible.
Moving parts hazard.
Risk of personal injury.
Caution: Be SURE no scale remover contacts the
bearing.
14. Return the ice sweep to its original position.
15. Press and HOLD the both the On and Off buttons
for 5 seconds. The Time to Clean light will blink on
and off.
16. After 40 minutes (20 of no ice making and 20
Ice
making ice) the ice machine and all the control
Sweep
panel lights will shut off.
17. After ice making starts, continuously add scale
remover solution to the reservoir to keep it about
half full.
18. When all remaining solution is used, rotate
the float valve knob to the ON position. Ice will
continue to be made.
19. Rotate float valve lever to Off and pull the drain
plug again to drain the system, then replace it.
20. Pour a gallon of hot (95
ice storage bin to flush out the drain and melt all
ice that was made during the cleaning process. Be
sure all ice is melted.
Breaker
Note: Only add 16 oz or 1/2 liter water to the bin at a
time, as excess water will drain out the spout.
21. Rotate float valve knob to the ON position.
22. Push and release the On button to restart ice
making.
23. Operate the machine for 15 minutes and then
pour water onto the ice in the bin until it has all
been melted.
Note: Only add 16 oz or 1/2 liter water to the bin at a
time, as excess water will drain out the spout.
24. Rotate the float valve knob to the off position.
25. Locate reservoir drain and pull its drain plug out to
drain the reservoir and evaporator. When draining
is complete, return the plug to its original position.
26. Rotate the float valve to the ON position and allow
the reservoir to fill up with water. Cleaning out any
traces left of scale remover.
27. Once the reservoir is full, rotate the float valve to
the off position and pull its drain plug out to drain
the reservoir and evaporator. When draining is
complete, return the plug to its original position.
28. To continue, see the Sanitizing section for next
steps.