MAINTENANCE
This is a low-maintenance device. Nevertheless, you must perform regular visual inspections.
Always check the device for damage before use. There are no parts inside the unit that require
maintenance.
N OTICE
Do not use the device if it is visibly damaged.
10
TROUBLESHOOTING
N OTICE
»
Do not make any inappropriate changes or modifications to the device.
»
Contact the Service department if repairs are required.
If the device malfunctions or is found to be defective in any other way, even after the solutions
suggested below have been followed, contact the manufacturer. You will find the contact details
in Chapter 19.
Fault/problem
Voltage loss/leakage
from the fence
Power leakage or
short-circuit of fence
connection
Poor grounding
Fence voltage
insufficient
34
Solution
Remove vegetation from the fence (by mowing or pruning).
Check whether the insulators are defective (recognisable by
"clicking" and, possibly, sparking of insulators). Replace defective
and weather-worn insulators.
Check whether the conductor material is touching the ground (e.g.
as a result of breakage, insufficient mechanical tension). Repair
the fencing. Use only special connection pieces and tighten the
conductor material.
Check whether the conductor material possesses any undesirable
properties (thin conductor, high resistance). Use high-quality
conductor material with a low resistance and large diameter. Ensure
that the conductor material has high-quality wiring.
Make sure that the conductor material is not connected using tied
knots, and that the connection is adequate. Use suitable special
connection pieces for the conductor material.
Do not use any conventional cables for the fence connection. We
recommend the use of a high voltage cable (Item no. 32611).
Follow the tips given in Section 6.4.
Check whether the grounding rod is corroded. Replace corroded
grounding rods.
Check whether the cables/connections are intact. Replace defective
parts.
Fence too long. Reduce the area or use a more powerful energiser.
INSTRUCTION MANUAL VOSS.FARMING IMPULS