Connection of the main PCB
2-way
valve
Signal inputs
L N =AC230V, Heat, Cool=Thermostat heat, Cool
Optional Thermostat
terminal
Dry contact Vcc-Bit1, Vcc-Bit2 open/short
OLP for booster
(System setup necessary)
heater
It is connected to the safety device (OLP) of
DHW tank.
Dry contact Open=not operate, Short=operate
(System setup necessary)
External control
Able to turn ON/OFF the operation by external
switch
Connected (Please use 2 cores wire for relocation
Remote controller
and extension. Total cable length shall be 50m
or less.)
Outputs
AC230V N=Neutral Open, Close=direction (For
3-way valve
circuit switching when connected to DHW tank)
AC230V N=Neutral Open, Close (Prevent water
2-way valve
circuit pass through during cooling mode)
AC230V (Used when Indoor Unit pump capacity is
Extra pump
insuffi cient)
AC230V (Used when using booster heater in DHW
Booster heater
tank)
Boiler contact/
Dry contact (System setup necessary)
Defrost signal
Thermistor inputs
Zone 1 room sensor PAW-A2W-TSRT
PAW-A2W-TSOD (Total cable length shall be
Outdoor air sensor
30m or less)
Tank sensor
Please use Panasonic specifi ed part
Buffer tank sensor
PAW-A2W-TSBU
Connection of Optional PCB (CZ-NS5P)
Optional
thermostat 2
L
N Cool Heat
Pool
Pump
Solar
Pump
Error
signal
Zone 1
Pump
Zone 2
Pump
Zone 2
room
sensor
18
OLP for booster heater
Zone 1 room sensor
External control
Remote controller
Outdoor air sensor
Buffer Tank sensor
Tank sensor
Boiler contact/
Defrost signal
Extra pump
Booster heater
3-way
Room
valve
thermostat 1
Mixing
Mixing
valve 1
valve 2
N
O
C
N
O
C
Pool
Zone 2
Zone 1
Demand
Solar
sensor
water
water
water
signal
sensor
sensor
sensor
Signal inputs
Optional Thermostat
SG signal
Heat/Cool SW
External comp.SW
Demand signal
Outputs
AC230V N=Neutral Open,
Mixing valve
Close=mixture direction
Operating time: 30s~120s
Pool pump
AC230V
Solar pump AC230V
Zone pump AC230V
Thermistor inputs
Zone room sensor
Pool water sensor
Zone water sensor
Solar sensor
Recommended External Device Specifi cation
• This section explains about the external devices (optional)
recommended by Panasonic. Please always ensure to use the
correct external device during system installation.
• For optional sensor.
1. Buffer tank sensor: PAW-A2W-TSBU
Use for measurement of the buffer tank temperature.
Insert the sensor into the sensor pocket and paste it on the
buffer tank surface.
2. Zone water sensor: PAW-A2W-TSHC
Use to detect the water temperature of the control zone.
Mount it on the water piping by using the stainless steel metal
strap and contact paste (both are included).
Dimensions (mm)
35
3. Outdoor sensor: PAW-A2W-TSOD
If the installation location of the outdoor unit is exposed to direct
sunlight, the outdoor air temperature sensor will be unable to
measure the actual outdoor ambient temperature correctly.
In this case, optional outdoor temperature sensor can be fi xed
at a suitable location to more accurately measure ambient
temperature.
Dimensions (mm)
Ext.
comp.
SW
Heat/
46
Cool
SW
Bit1
SG
Bit2
signal
Vcc
L N =AC230V, Heat, Cool=Thermostat heat, Cool
terminal
Dry contact Vcc-Bit1, Vcc-Bit2 open/short
(System setup necessary)
Switching SW (Please connect to the 2 contacts
controller)
Dry contact Open=Heat, Short=Cool (System
setup necessary)
Dry contact Open=Comp.OFF, Short=Comp.ON
(System setup necessary)
DC 0~10V (System setup necessary)
Please connect to the DC 0~10V controller.
AC 230V, 0.6 A max
AC 230V, 0.6 A max
AC 230V, 0.6 A max
PAW-A2W-TSRT
PAW-A2W-TSHC
PAW-A2W-TSHC
PAW-A2W-TSSO
Dimensions (mm)
blue
black
brown
93
93
AC230V, 6VA
Ø6
40
70
70