Descargar Imprimir esta página

Panasonic WH-SDC0509L3E5 Manual De Instalación página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 34
SELECT THE BEST LOCATION
1
Before choosing the installation site, obtain user approval.
 There should not be any heat source or steam near the Indoor Unit.
 A place where air circulation in the room is good.
 A place where drainage can be easily done (e.g. Utility room).
 A place where Indoor Unit's operation noise will not cause discomfort to
the user.
 A place where Indoor Unit is far from door way.
 Ensure to keep minimum distance of spaces as illustrated below from wall,
ceiling, or other obstacles.
 A place where fl ammable gas leaking might not occur.
 Recommended installation height for Indoor Unit shall be at least 1150 mm.
 Must install on a vertical wall.
 When install electrical equipment at wooden building of metal lath or wire
lath, according to electrical facility technical standard, no electrical contact
between equipment and building is allowed. Insulator must be installed in
between.
 Do not install the unit at outdoor. This is designed for indoor installation only.
Required space for installation
100 mm
or more
HOW TO FIX INSTALLATION
2
PLATE
The mounting wall is strong and solid enough to prevent it from
More than 350
Wall
5
≥1956 from
ground
7
0
The centre of installation plate should be at more than 350 mm at
right and left of the wall.
The distance from installation plate edge to ground should more
than 1956 mm.
• Always mount the installation plate horizontally plate by aligning the
marking thread and using a level gauge.
• Mount the installation plate on the wall with 6 sets of plug, bolt and
washer (all non-supply) with size M8.
4
100 mm
or more
100 mm
or more
1150 mm
or more
vibration
More than 350
Wall
5
Installation
plate 1
Indoor Unit
body
Bolt -
size M8
Installation plate 4
1
6
0
200
TO DRILL A HOLE IN THE
3
WALL AND INSTALL A
SLEEVE OF PIPING
1. Make a through hole. (Check pipe diameter and insulation thickness)
2. Insert the piping sleeve to the hole.
3. Fix the bushing to the sleeve.
4. Cut the sleeve until it extrudes about 15 mm from the wall.
When the wall is hollow, please be sure to use the sleeve for
tube assembly to prevent dangers caused by mice biting the
connection cable.
5. Finish by sealing the sleeve with putty or caulking compound at the
fi nal stage.
Sleeve for tube
assembly
Through hole
INDOOR UNIT INSTALLATION
4
This section is for authorized and licensed electrician/water system
installer only. Work behind the front plate secured by screws
must only be carried out under supervision of qualifi ed contractor,
installation engineer or service person.
Access to Internal Components
Please follow the steps below for take out front plate. Before removing the
front plate of Indoor Unit, always switch off all power supply (i.e. Indoor Unit
(Unit in mm)
power supply, heater power supply).
1. Remove the 2 mounting screws which located at bottom of the front
plate.
2. Gently pull the lower section of the front plate towards you to remove
the front plate from left and right hooks.
3. Hold the left edge and right edge of front plate to lift up front plate from
hooks.
Screws
CAUTION
Wall
Outdoor
Indoor
15 mm
Bushing for tube assemblys
Putty or caulking compound
WARNING
Approx. 5 - 7 mm
Hook
Lift up

Publicidad

loading

Este manual también es adecuado para:

Wh-sdc0509l6e5