WIRE STRIPPING AND CONNECTING REQUIREMENT
Wire stripping
No loose strand
when insert
Conductor
fully insert
ACCEPT
CONNECTING REQUIREMENT
For Indoor Unit WH-SDC0509L3E5 with
WH-WDG05LE5*, WH-WDG07LE5*, WH-WDG09LE5*
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and
can be connected to current supply network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-3 and
can be connected to current supply network.
For Indoor Unit WH-SDC0509L6E5 with
WH-WDG05LE5*, WH-WDG07LE5*, WH-WDG09LE5*
The equipment's Power Supply 1 complies with IEC/EN 61000-3-2.
The equipment's Power Supply 1 complies with IEC/EN 61000-3-3 and
can be connected to current supply network.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-12.
The equipment's Power Supply 2 complies with IEC/EN 61000-3-11
and shall be connected to suitable supply network, with the following
maximum permissible system impedance Z
interface. Please liaise with supply authority to ensure that the Power
Supply 2 is connected only to a supply of that impedance or less.
INSTALLATION OF REMOTE
6
CONTROLLER AS ROOM
THERMOSTAT
• Remote Controller 3 mounted to the Indoor Unit can be moved to
the room and serve as Room Thermostat.
Installation Location
• Install at the height of 1 to 1.5 m from the fl oor (Location where
average room temperature can be detected).
• Install vertically against the wall.
• Avoid the following locations for installation.
1. By the window, etc. exposed to direct sunlight or direct air.
2. In the shadow or backside of objects deviated from the room
airfl ow.
3. Location where condensation occurs (The Remote Controller is
not moisture proof or drip proof.)
4. Location near heat source.
5. Uneven surface.
• Keep distance of 1 m or more from the TV, radio and PC. (Cause
of fuzzy image or noise)
Indoor/outdoor
connecting
terminal board
5mm or more
(gap between wires)
Conductor
Conductor not
over insert
fully insert
PROHIBITED
PROHIBITED
= 0.123 ohm ( ) at the
max
Remote Controller Wiring
Indoor Unit
Remote Controller wiring
(fi eld supply)
• No polarity
Terminal for Remote Controller wiring
• Remote Controller cable shall be (2 x min 0.3 mm²), of double
insulation PVC-sheathed or rubber sheathed cable. Total cable
length shall be 50 m or less.
• Be careful not to connect cables to other terminals of Indoor Unit
(e.g. power source wiring terminal). Malfunction may occur.
• Do not bundle together with the power source wiring or store in
the same metal tube. Operation error may occur.
Remove The Remote Controller From Indoor Unit
1. Remove both Left Decoration Panel e and Right Decoration
Panel f from Front Plate 1 with gently push the panels from
back.
2. Remove the 4 screws and take out the holder with Remote
Controller 3.
Remove 4 screws
3. Remove the top case from the bottom case.
Bottom case
Remote Controller
1
2
Gently push
from rear
Top case
Insert the
driver and
slightly turn.
Flat-blade
screwdriver
7