Operating Environment:
Temperature ........................................... 0... 40°C (32... 104°F)
Humidity ................................................. Maximum of 95% non-condensing
Storage Temperature ............................. –20... 60°C (-4... 140°F)
3
Function of the Unit
3.1
Overview
1
Camera head
2
Positioning probe
3
Bending spring
4
Reel cable
5
Monitor unit
5.1
Push button monitor unit
6
Reel
3.2
Working notes
- Do not bend the reel cable! The cable may break!
- Do not pull the reel cable over sharp edges! The cable may become damaged!
ATTENTION! Always protect ROCAM mini HD AMPShare against water, and use
only recommended indoors. Only the camera head (1) and reel cable (4) may come
into contact with water!
3.3
Battery
Charging the battery:
Use only the chargers listed in the technical data. Only these chargers are matched to
the lithium-ion battery of your power tool!
Note: Lithium-ion rechargeable batteries are supplied partially charged according to international
transport regulations. To ensure full rechargeable battery capacity, fully charge the rechargeable
battery before using your tool for the first time.
Inserting the Battery:
Push the charged battery into the battery holder until it clicks into place.
Removing the Battery:
To remove the rechargeable battery, press the battery re-lease button and pull the battery out.
Do not use force to do this.
The rechargeable battery has two locking levels to prevent the battery from falling out if the bat-
tery release button is pressed unintentionally. The rechargeable battery is held in place by a
spring when fitted in the power tool.
Battery charge indicator:
The green LEDs on the battery charge indicator indicate the state of charge of the battery. For
safety reasons, it is only possible to check the state of charge when the power tool is not in op-
eration.
Press the button for the battery charge indicator
so possible when the battery is removed.
If no LED lights up after pressing the button for the battery charge indicator, then the battery is
defective and must be replaced.
The state of charge of the battery is also displayed on the user interface Status indications.
20
7
Frame
8
Holder
9
Camera cable
10
Monitor bracket
11
Battery release
12
Battery
or
to show the state of charge. This is al-
ENGLISH
(A)