MAINTENANCE
11.3 REMOVING THE FUME ADAPTER
To remove the fume adapter, proceed as follows:
- open the door of the appliance –, consult the paragraph
the
door"
- remove the upper fire bricks, consult the paragraph
fire
bricks"
- loosen the fixing screws and remove the fume adapter from the
inside; disconnect any pipes present.
Perform the above procedure in reverse order to mount the fume
adapter.
a
The fume connector is fitted with a seal that could
get damaged when dismantling the component. Be-
fore putting the fume connector back on, verify that
the seal is intact; if not, it must be replaced.
CS.STB.IST-1_EN_Rev.1.0_08-23
11.4 EXTRACTING THE COMBUSTION CHAMBER
To extract the combustion chamber, proceed as follows:
"Opening
- we suggest removing the frame to avoid damaging it, consult the
paragraph
"Removing the
- open the door of the appliance –, consult the paragraph
the
door"
- remove the upper fire bricks, consult the paragraph
fire
bricks"
- remove the fume connector, consult the paragraph
fume
adapter"
- loosen the fixing screws (1) and extract the combustion chamber
(2).
Su
Fig. 36
To mount the combustion chamber, perform the above procedure in
reverse order.
"Frame
removal"
2
EN
"Opening
"Removing the
"Removing the
x2
1
Fig. 37
29