Descargar Imprimir esta página

Poolex ICE SPA Manual De Usuario Y Instalacion página 110

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
3. INSTALLATION
3.5
Operation
Use conditions
For the heat pump to operate normally, the ambient air temperature must be between -25°C
and 43°C.
Advance notice
Prior to starting the heat pump, please:
Check that the equipment is secure and stable.
Check that the gauge indicates a pressure greater than 80 psi.
Check that the electrical wiring is properly connected to the terminals.
Check the earthing connections.
Check that the hydraulic connections are tight and that there is no leakage of water.
Check that the water is circulating correctly in the heat pump and that the flow rate is
adequate
Remove any object that is not required around the equipment and all tools.
Operation
1. Connect the power supply to the device.
2. Start the filtration pump.
3. Activate the device's electrical supply protection (differential switch situated on the power
cable).
4. Start the heat pump.
5. Select the desired temperature using one of the modes appearing on the control panel.
6. The heat pump's compressor will start shortly after.
And you just need to wait for the target temperature to be reached.
WARNING: Under normal conditions, a suitable heat pump can heat up the
tub water by 1°C to 2°C per hour. It is therefore normal that you do not feel any
difference in temperature at the outlet level when the heat pump is on.
A heated tub must be covered and insulated to avoir any heat loss.
Good to know: restart after power failure
After a power failure or a usual interruption, turn the power back on, the system is on sleep mode.
Restart the differential plus and switch on the heat pump.
12 |
EN

Publicidad

loading