Descargar Imprimir esta página

Poolex ICE SPA Manual De Usuario Y Instalacion página 128

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
7. MAINTENANCE AND REPAIRS
Under normal conditions, a suitable heat pump can heat up the tub water by 1°C to 2°C per
hour. It is therefore normal that you do not feel any difference in temperature at the outlet
level when the heat pump is on.
A heated tub must be covered and insulated to avoir any heat loss.
7.3
Breakdown and faults
In the event of a problem, the heat pump's screen displays an error code instead of temperature
indications. Please consult the table below to find the possible causes of a fault and the actions to
be taken.
Code
E01
Discharge temperature failed
E05
Coil temperature failed
E09
Suction temperature failed
E19
Water inlet temperature failed
E21
Controller communication failed
E22
Ambient temperature failed
E25
Water flow switch failed
Communication failed between PCB and
E27
compressor driver
E28
EEPROM communication failed
S06
Low voltage protection
S11
Discharge temperature too high protection
S25
Ambient temperature too low protection
S27
Coil temperature too high protection
30 |
EN
Anomaly detected
Resolution
Check the water flow
Check the temperature sensor
Check the temperature sensor
Check the temperature sensor
1. Check the wire connection
2. Replace the controller
3. Replace main PCB
Check the temperature sensor
Check the water flow
1. Check the wire connection
2. Replace outdoor PCB
3. Replace the compressor driver
1. Check the wire connection
2. Replace EEPROM
3. Replace the controller
1. Check the fan motor
2. Check the water flow
3. Check if the EEV is open
1. Check the temperature sensor
2. Check if the fan motor is working correctly when
cooling
3. Check the throttling
1. Check if any resist around the heat pump
2. Check the water flow when cooling
1. Check the fan motor
2. Check for barriers around the evaporator

Publicidad

loading