7. MAINTENANCE AND REPAIRS
Code
r01
Compressor over current
r02
Compressor startup failed
r03
DC fan motor A failed
r04
DC fan motor B failed
r05
IPM overheat stut down
r06
AC input current too high
r08
PCB communication failed
r10
DC bus overvoltage
r11
DC bus undervoltage
r12
AC input overvoltage failed
r13
AC input undervoltage failed
r16
EEPROM failed
r23
Compressor phase loss
Current sampling signal overcurrent
r25
(hardware overcurrent)
Other problem
The spa filtration pump is running continuously.
»
Check the filtration time setting on the spa control box and adjust if necessary.
Tip: Minimum filtration time for an indoor spa is 5 hours, for an outdoor spa 8 hours.
»
However, if you wish to reduce this circulation time, adjust the temperature on the spa
control box to the same set temperature as on the heat pump.
Anomaly detected
Resolution
1. Check the input voltage
2. Check the water flow
3. Check the throttling
4. Check the heat exchange around the heat pump
Check input voltage
1. Check the wire connection of fan motor
2. Check if any block of fan motor
1. Check the wire connection of fan motor
2. Check if any block of fan motor
1. Check the fan motor
2. Replace IPM board/compressor driver
Check input power supply
1. Check the wire connection
2. Replace PCB
3. Replace compressor driver
Check input power supply
Check input power supply
Check input power supply
Check input power supply
1. Replace main PCB
2. Update the software
1. Check the input power supply
2. Check the wire connection
1. Check input power supply
2. Check if any resist around the heat pump
3. Check the water flow
EN
| 31